Acetabular revision with a 7-mm lateral offset component inserted without cement in patients who have acetabular deficiency

被引:8
作者
McGrory, BJ
机构
[1] Univ Vermont, Sch Med, Dept Orthopaed Surg & Rehabil, Burlington, VT 05405 USA
[2] Maine Joint Resplacement Inst, Portland, ME USA
关键词
cementless; cups; hip; arthroplasty; offset; torsion;
D O I
10.1016/j.arth.2004.09.031
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The lateral offset acetabular component, a reconstruction technique for hips with acetabular bone loss, causes a torsional moment because of the displacement of the center of hip rotation and may increase the risk of fixation failure. Eighteen patients who had an acetabular revision with a 7-mm offset cementless component were retrospectively studied to identify factors that influence outcome and to clarify indications for its use. The average follow-up time was 47 months and all patients were followed up for a minimum of 2 years or until the failure of the fixation. At the latest follow-up examination, 3 of the 18 cups had been revised for loosening, 1 cup had radiographic loosening, and 1 patient was considered a clinical failure. Clinical or radiographic failure was significantly more likely (P <.05) in patients with a higher shelf abduction angle. On the basis of the definitive failures in more than one fourth of reconstructions at early follow-tip, the routine use of this component is not recommended ill revision surgery with acetabular deficiency. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:443 / 453
页数:11
相关论文
共 15 条
[1]
Azuma T, 1985, Nihon Seikeigeka Gakkai Zasshi, V59, P269
[2]
Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency [J].
Chen, WM ;
Engh, CA ;
Hopper, RH ;
McAuley, JP ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (02) :197-206
[3]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[4]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[5]
Offset acetabular components introduce torsion on the implant and may increase the risk of fixation failure [J].
Giori, NJ .
JOURNAL OF ARTHROPLASTY, 2003, 18 (01) :89-91
[7]
Long-term behaviour of the Charnley offset-bore acetabular cup [J].
Ioannidis, TT ;
Zacharakis, N ;
Magnissalis, EA ;
Eliades, G ;
Hartofilakidis, G .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :48-53
[8]
MCGRORY BJ, 1997, MEDSCAPE ORTHOP SPOR, V1, P1997
[9]
Paprosky W G, 1994, J Arthroplasty, V9, P33, DOI 10.1016/0883-5403(94)90135-X
[10]
Polyethylene wear and acetabular component orientation [J].
Patil, S ;
Bergula, A ;
Chen, PC ;
Colwell, CW ;
D'Lima, DD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :56-63