Preliminary report of detecting microembolic signals in transcranial Doppler time series with nonlinear forecasting

被引:7
作者
Keunen, RWM
Stam, CJ
Tavy, DLJ
Mess, WH
Titulaer, BM
Ackerstaff, RGA
机构
[1] Leyenburg Hosp, Dept Neurol & Clin Neurophysiol, NL-2545 CH The Hague, Netherlands
[2] Antonius Hosp Nieuwegein Utrecht, Dept Clin Neurol & Neurophysiol, Utrecht, Netherlands
关键词
emboli; ultrasonics; cerebrovascular diseases; nonlinear analysis;
D O I
10.1161/01.STR.29.8.1638
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Most algorithms used for automatic detection of microembolic signals (MES) are based on power spectral analysis of the Doppler shift. However, controversies exist as to whether these algorithms can replace the human expert. Therefore, a different algorithm was applied that takes advantage of the periodicity of the MES. This so-called nonlinear forecasting (NLF) is able to detect periodicity in a time series, and it is hypothesized that this technique has the potential to detect MES. Moreover, because of the lack of prominent periodicity in both the normal Doppler signals (DS) and movement artifacts (MA), the NLF has a potential to differentiate MES from normal blood flow variations and MA. Methods-Twenty single MES and 100 MA were selected by 2 human experts. NLF was applied to MES and MA and compared with 200 randomly chosen DS. NLF resulted in a so-called prediction value that ranges from +1 in signals with prominent periodicity to 0 in signals that lack periodicity. Results-NLF revealed that MES are more predictable than the normal Doppler signals (prediction [MES]=0.829+/-0.084 versus prediction [DS]=-0.060+/-0.228; P<0.0001). Moreover, MES are more predictable than the MA (prediction [MA] = -0.034+/-0.223; P<0.0001). No difference in prediction could be found between DS and MA. Conclusions-This preliminary report shows that MES can be separated from DS and MA by NLF. Research is needed as to whether this technology can be further developed fdr automatic detection of MES.
引用
收藏
页码:1638 / 1643
页数:6
相关论文
共 18 条
  • [1] Kaplan Daniel, 1995, Understanding Nonlinear Dynamics
  • [2] DETERMINING EMBEDDING DIMENSION FOR PHASE-SPACE RECONSTRUCTION USING A GEOMETRICAL CONSTRUCTION
    KENNEL, MB
    BROWN, R
    ABARBANEL, HDI
    [J]. PHYSICAL REVIEW A, 1992, 45 (06): : 3403 - 3411
  • [3] COMPUTERIZED DETECTION OF CEREBRAL EMBOLI AND DISCRIMINATION FROM ARTIFACT USING DOPPLER ULTRASOUND
    MARKUS, H
    LOH, A
    BROWN, MM
    [J]. STROKE, 1993, 24 (11) : 1667 - 1672
  • [4] TRANSCRANIAL DOPPLER DETECTION OF CIRCULATING CEREBRAL EMBOLI - A REVIEW
    MARKUS, H
    [J]. STROKE, 1993, 24 (08) : 1246 - 1250
  • [5] Use of a decibel threshold in detecting Doppler embolic signals
    Markus, HS
    Molloy, J
    [J]. STROKE, 1997, 28 (04) : 692 - 695
  • [6] Intercenter agreement in reading Doppler embolic signals - A multicenter international study
    Markus, HS
    Ackerstaff, R
    Babikian, V
    Bladin, C
    Droste, D
    Grosset, D
    Levi, C
    Russell, D
    Siebler, M
    Tegeler, C
    [J]. STROKE, 1997, 28 (07) : 1307 - 1310
  • [7] MICROEMBOLIC SIGNAL-DETECTION USING ULTRASOUND
    MARKUS, HS
    HARRISON, MJ
    [J]. STROKE, 1995, 26 (09) : 1517 - 1519
  • [8] RECONSTRUCTION EXPANSION AS A GEOMETRY-BASED FRAMEWORK FOR CHOOSING PROPER DELAY TIMES
    ROSENSTEIN, MT
    COLLINS, JJ
    DE LUCA, CJ
    [J]. PHYSICA D-NONLINEAR PHENOMENA, 1994, 73 (1-2) : 82 - 98
  • [9] REAL-TIME IDENTIFICATION OF CEREBRAL MICROEMBOLI WITH US FEATURE DETECTION BY A NEURAL-NETWORK
    SIEBLER, M
    ROSE, G
    SITZER, M
    BENDER, A
    STEINMETZ, H
    [J]. RADIOLOGY, 1994, 192 (03) : 739 - 742
  • [10] DETECTION OF INTRACRANIAL EMBOLI IN PATIENTS WITH SYMPTOMATIC EXTRACRANIAL CAROTID-ARTERY DISEASE
    SIEBLER, M
    SITZER, M
    STEINMETZ, H
    [J]. STROKE, 1992, 23 (11) : 1652 - 1654