The clinical value of ambulatory urethral pressure recording in women

被引:4
作者
Kulseng-Hanssen, S [1 ]
机构
[1] Boerum Hosp, Dept Obstet & Gynaecol, N-1306 Boerum, Norway
来源
SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY | 2001年 / 35卷
关键词
ambulatory urethral pressure recording; ambulatory urodynamic monitoring; genuine stress incontinence; mixed incontinence; low urethral closure pressure; conductance leak detector; unstable urethra;
D O I
10.1080/003655901750174935
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The value of ambulatory urethral pressure recording (AUPR) was evaluated by reviewing both data from 116 patients investigated and Ambulatory Urodynamic Monitoring (AUM) tracings. Typical tracings are shown from conditions where we find that AUPR is of value. (i) Stress incontinence where a patient who complains of stress incontinence does not leak during the stress test, but leaks while jumping on a trampoline. (ii) Mixed incontinence-in only 43% of patients complaining of both urge ands stress incontinence mixed incontinence was documented by AUM. Thirty-six per cent of patients complaining of both urge and stress incontinence were found to be stress incontinent and 21% were leaking due to an unstable detrusor. (iii) Urethral closure pressure of 20 cmH(2)O or less (low urethral closure pressure; LUCP). LUCP was found in 13% of the patients. Patients with LUCP may leak due to stress, unstable detrusor or unstable urethra. We conclude that ambulatory recording of both urethral and bladder pressures in addition to leakage may contribute to a more complete diagnosis and treatment in these conditions.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 19 条
[1]  
Anders K., 1997, Neurourology and Urodynamics, V16, P510
[2]   CONTINUOUS AMBULATORY URODYNAMIC MONITORING [J].
BHATIA, NN ;
BRADLEY, WE ;
HALDEMAN, S ;
JOHNSON, BK .
BRITISH JOURNAL OF UROLOGY, 1982, 54 (04) :357-359
[3]   Ambulatory urodynamic monitoring [J].
Grant, JM .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1996, 103 (05) :R21-R21
[4]  
Kulseng-Hanssen S., 1999, Neurourology and Urodynamics, V18, P300
[5]  
Kulseng-Hanssen S, 1998, ACTA OBSTET GYN SCAN, V77, P12
[6]  
KulsengHanssen S, 1996, SCAND J UROL NEPHROL, V30, P27
[7]   AMBULATORY URETHRO-CYSTO-RECTOMETRY - A NEW TECHNIQUE [J].
KULSENGHANSSEN, S ;
KLEVMARK, B .
NEUROUROLOGY AND URODYNAMICS, 1988, 7 (02) :119-130
[8]  
KULSENGHANSSEN S, 1995, 25 ANN M INT CONT SO
[9]  
KULSENGHANSSEN S, 1997, 27 ANN M INT CONT SO
[10]  
Rosario DJ, 1999, NEUROUROL URODYNAM, V18, P223, DOI 10.1002/(SICI)1520-6777(1999)18:3<223::AID-NAU9>3.0.CO