Validation of the Tracmor triaxial accelerometer system for walking

被引:68
作者
Levine, JA
Baukol, PA
Westerterp, KR
机构
[1] Mayo Clin & Mayo Fdn, Endocrine Res Unit, Rochester, MN 55905 USA
[2] Univ Maastricht, Dept Human Biol, Maastricht, Netherlands
关键词
energy expenditure; movement registration; physical activity;
D O I
10.1097/00005768-200109000-00024
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: Walking is likely to contribute substantially to nonexercise activity thermogenesis. The Tracmor triaxial accelerometer system (Maastricht, The Netherlands) is the most widely validated system for detecting body movement in free-living subjects. The aim of this study was to validate the Tracmor triaxial accelerometer system for estimating the energy expenditure of walking. Methods: Experiments were conducted in healthy subjects. First, baseline variability for Tracmor output was determined for subjects standing still. Second, Tracmor output was compared for walking on a treadmill and on level around. Third, both Tracmor output and energy expenditure were compared for walking on a treadmill and walking on level ground. Finally, the effect of gradient on Tracmor output and energy expenditure was compared for subjects walking on a treadmill. Results: The data demonstrated excellent reproducibility for comparing Tracmor output for standing (CV < 2%). There were excellent log-linear relationships between velocity and Tracmor output walking on a treadmill (r = 0.998) and on level ground (r = 0.999). Tracmor output and the energy expenditure of walking were inseparable for the two modalities of walking. However, the variance in response was such that to reliably derive the relationship between Tracmor output and energy expenditure, separate regression equations are needed for each subject. Finally, the Tracmor accelerometer did not detect the increased energy expenditure of walking that occurs as gradient increases. Conclusion: The Tracmor triaxial accelerometer provides reproducible and reliable data on the body motion associated with walking regardless of whether a subject walks on a treadmill or level ground. Tracmor units can be used to predict the energetic cost of walking provided that separate regression equations are derived for each subject to convert Tracmor output to energy expenditure.
引用
收藏
页码:1593 / 1597
页数:5
相关论文
共 17 条
[1]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[2]  
BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
[3]   Daily physical activity assessment: Comparison between movement registration and doubly labeled water [J].
Bouten, CVC ;
VerboeketVandeVenne, WPHG ;
Westerterp, KR ;
Verduin, M ;
Janssen, JD .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) :1019-1026
[4]   A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity [J].
Bouten, CVC ;
Koekkoek, KTM ;
Verduin, M ;
Kodde, R ;
Janssen, JD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) :136-147
[5]   Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walking [J].
Bouten, CVC ;
Sauren, AAHJ ;
Verduin, M ;
Janssen, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) :50-56
[6]  
BOUTEN CVC, 1995, THESIS EINDHOVEN U E
[7]  
GOLDBERG GR, 1990, EUR J CLIN NUTR, V44, P99
[8]  
HAYMES EM, 1993, MED SCI SPORT EXER, V25, P1365
[9]   Physical activity related energy expenditure in children by doubly labeled water as compared with the Caltrac accelerometer [J].
Johnson, RK ;
Russ, J ;
Goran, MI .
INTERNATIONAL JOURNAL OF OBESITY, 1998, 22 (11) :1046-1052
[10]   Role of nonexercise activity thermogenesis in resistance to fat gain in humans [J].
Levine, JA ;
Eberhardt, NL ;
Jensen, MD .
SCIENCE, 1999, 283 (5399) :212-214