A new method to obtain total power receiver equivalent noise temperature

被引:2
作者
Aja, B [1 ]
Pascual, JP [1 ]
de la Fuente, L [1 ]
Gallegos, J [1 ]
Artal, E [1 ]
机构
[1] Univ Cantabria, Dept Ingn Comunicac, Santander 39005, Spain
来源
33RD EUROPEAN MICROWAVE CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS | 2003年
关键词
D O I
10.1109/EUMA.2003.340963
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A method to obtain more accurate noise temperature of a radiometer at room temperature using commercial noise sources is presented. A low noise amplifier used in a radiometer system has an equivalent noise temperature which adds the contributions of its equivalent noise temperature at each frequency over its operating frequency range. The Y-factor has been improved and generalised to take into account the dependence with frequency of the noise source and the transfer function of a receiver. This dependence is especially relevant for broadband radiometer systems. A commercial simulator is used to validate the method and a Ka-band total power radiometer is characterized following the proposed method.
引用
收藏
页码:355 / 358
页数:4
相关论文
共 4 条
[1]  
[Anonymous], 2005, SOM MED
[2]  
ARTAL E, 2001, 31 EUR MICR C C P LO, V2, P61
[3]  
Fernandez J. E., 1998, TMO Prog. Rep. 42-135, P1
[4]  
RODDIS N, 2003, O ESA WORKSH MILL WA, P81