Fluidic preconcentrator device for capillary electrophoresis of proteins

被引:68
作者
Astorga-Wells, J
Swerdlow, H [1 ]
机构
[1] Karolinska Inst, Dept Med Biochem & Biophys, SE-17177 Stockholm, Sweden
[2] Karolinska Inst, Ctr Genom Res, SE-17177 Stockholm, Sweden
关键词
D O I
10.1021/ac0300892
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new preconcentration device was developed for analysis of proteins by capillary electrophoresis (CE). The microfluidic device uses an electric field to capture proteins that pass through the system. The capture zone is maintained in the flow stream by the interaction between hydrodynamic and electrical forces. The device consists of a flow channel made of PEEK tubing with two electrical junctions, each of which is covered with a conductive membrane. A syringe pump provides the flow stream and also allows the injection of up to 13.5 muL of a dilute sample. The system can be easily connected to a CE device postcapture for off-line preconcentration of proteins. For the proteins used in this study, preconcentration factors up to 40-fold can be achieved. CE detection limits for bovine carbonic anhydrase, a-lactalbumin and beta-lactoglobulins A and B were in the nanomolar range using UV detection at 200 nm. Preconcentration is dependent on both time and initial protein concentration. We show the possibility of using an off-fine fluidic preconcentrator device employing counterflow capillary electrophoresis with minimum sample manipulation, achieving detection limits similar to on-line approaches.
引用
收藏
页码:5207 / 5212
页数:6
相关论文
共 28 条
[1]  
ALBIN M, 1993, ANAL CHEM, V65, P489
[2]  
ASTORGAWELLS J, IN PRESS ANAL CHEM
[3]   Quantitative trace analysis of interleukin-3, interleukin-6, and basic model proteins using isotachophoresis-capillary zone electrophoresis with hydrodynamic counterflow [J].
Bergmann, J ;
Jaehde, U ;
Schunack, W .
ELECTROPHORESIS, 1998, 19 (02) :305-310
[4]   Characterization of a solid-phase extraction device for discontinuous on-line preconcentration in capillary electrophoresis-based peptide mapping [J].
Bonneil, E ;
Waldron, KC .
JOURNAL OF CHROMATOGRAPHY B, 1999, 736 (1-2) :273-287
[5]  
BOOKMAN P, 1986, DEV IONIC POLYM, V2, P269
[6]  
Chankvetadze B, 1999, ELECTROPHORESIS, V20, P2680, DOI 10.1002/(SICI)1522-2683(19990901)20:13<2680::AID-ELPS2680>3.0.CO
[7]  
2-#
[8]   SAMPLE STACKING OF AN EXTREMELY LARGE INJECTION VOLUME IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1046-1050
[9]   FLOW COUNTERBALANCED CAPILLARY ELECTROPHORESIS [J].
CULBERTSON, CT ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :955-962
[10]  
Dolník V, 2001, ELECTROPHORESIS, V22, P4163, DOI 10.1002/1522-2683(200111)22:19<4163::AID-ELPS4163>3.0.CO