Estimates of the ocular wave aberration from pairs of double-pass retinal images

被引:47
作者
Iglesias, I [1 ]
Berrio, E [1 ]
Artal, P [1 ]
机构
[1] Univ Murcia, Dept Fis, Lab Opt, E-30071 Murcia, Spain
来源
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION | 1998年 / 15卷 / 09期
关键词
D O I
10.1364/JOSAA.15.002466
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We apply a computational technique to retrieve the wave aberration of the eye from the point-spread function obtained from pairs of double-pass retinal images. The method consists of an adapted pyramidal version of a nonlinear least-squares fitting procedure to a wave aberration expressed as an expansion in Zernike polynomials. Although the procedure provides accurate estimates of the wave aberration, it presents several drawbacks that are discussed in detail. In particular, since a great deal of computational time is necessary to retrieve a single wave aberration, this technique is not useful for real-time applications. We present results of wave aberrations in five normal subjects in the fovea for a 4-mm-pupil diameter. In every case there is a clear presence of comalike aberrations, while the third-order spherical aberration is usually smaller than previous estimates. The root-mean-square error in the retrieved wave aberration, when defocus and astigmatism were corrected, ranges from 0.24 to 0.5 wavelength. The particular values of the aberration coefficients present a large intersubject variability. (C) 1998 Optical Society of America.
引用
收藏
页码:2466 / 2476
页数:11
相关论文
共 28 条
  • [1] ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY
    ARTAL, P
    MARCOS, S
    NAVARRO, R
    WILLIAMS, DR
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02): : 195 - 201
  • [2] Optical modulation transfer and contrast sensitivity with decentered small pupils in the human eye
    Artal, P
    Marcos, S
    Iglesias, I
    Green, DG
    [J]. VISION RESEARCH, 1996, 36 (22) : 3575 - 3586
  • [3] DOUBLE-PASS MEASUREMENTS OF THE RETINAL-IMAGE QUALITY WITH UNEQUAL ENTRANCE AND EXIT PUPIL SIZES AND THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM
    ARTAL, P
    IGLESIAS, I
    LOPEZGIL, N
    GREEN, DG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (10): : 2358 - 2366
  • [4] RETRIEVAL OF WAVE-ABERRATION OF HUMAN EYES FROM ACTUAL POINT-SPREAD-FUNCTION DATA
    ARTAL, P
    SANTAMARIA, J
    BESCOS, J
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (08): : 1201 - 1206
  • [5] Berny F., 1969, OPTICAL INSTRUMENTS, P375
  • [6] Born M., 1985, PRINCIPLES OPTICS
  • [7] Variations in photoreceptor directionality across the central retina
    Burns, SA
    Wu, S
    He, JC
    Elsner, AE
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (09) : 2033 - 2040
  • [8] WAVE-FRONT ABERRATION OF THE EYE - A REVIEW
    CHARMAN, WN
    [J]. OPTOMETRY AND VISION SCIENCE, 1991, 68 (08) : 574 - 583
  • [9] Daniel M., 2006, Optical Shop Testing
  • [10] Fienup J. R., 1987, Image recovery: theory and application, V231, P275