Multianalyte quantification of vitamin B6 and B2 species in the nanomolar range in human plasma by liquid chromatography -: Tandem mass spectrometry

被引:94
作者
Midttun, O
Hustad, S
Solheim, E
Schneede, J
Ueland, PM
机构
[1] Univ Bergen, LOCUS Homocysteine & Related Vitamins, N-5021 Bergen, Norway
[2] Univ Bergen, Sect Pharmacol, Inst Med, N-5021 Bergen, Norway
关键词
D O I
10.1373/clinchem.2005.051169
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Homocysteine, a risk factor of cardiovascular disease, cognitive disorders, and pregnancy complications, exists at a point of metabolic convergence of several B vitamins, including vitamins B, and B, (riboflavin). Measurement of the various forms of these vitamins may be useful for the study of hyperhomocysteinemia as well as for the assessment of vitamin status. Methods: Plasma (60 ILL) was deproteinized by mixing with an equal volume of 50 g/L trichloroacetic acid that contained d(2)-pyridoxal 5'-phosphate, d(3)-pyridoxal, and d(8)-riboflavin as internal standards. Pyridoxal (PL), pyridoxal 5'-phosphate (PLP), pyridoxine WN), pyridoxine 5'-phosphate, pyridoxamine (PM), pyridoxamine 5'-phosphate, 4-pyridoxic acid (PA), riboflavin, flavin mononucleotide (FMN), and FAD were separated on a C, reversed-phase column, which was developed with an acetortitrile gradient in a buffer containing acetic acid and heptafluorobutyric acid. The analytes were detected by tandem mass spectrometry in the positive-ion mode. Results: The chromatographic run lasted 8 min. Within-and between-day CVs were 3%-20% and 6%-22%, respectively, and recoveries were 78%-163%. Limits of detection (signal-to-noise ratio = 5) were in the range 0.1-4.0 nmol/L, and the response was linear over several orders of magnitude. In samples from 94 healthy persons, we obtained median concentrations (nmol/L) of 35.4 for PLP, 16.9 for PL, 22.4 for PA, 10.3 for riboflavin, 7.5 for FMN, and 63.1 for FAD. PN and PM were also detected in some cardiovascular patients taking B-6 supplements Conclusions: This method based on liquid chromatography-tandem mass spectrometry measures all known plasma forms of vitamins B-6 and B-2 which span a wide range of polarity. The assay is characterized by simple sample processing with no derivatization, low sample volume requirement, and a short run time. (c) 2005 American Association for Clinical Chemistry.
引用
收藏
页码:1206 / 1216
页数:11
相关论文
共 70 条
[1]   THERMOSPRAY AND ELECTROSPRAY MASS-SPECTROMETRY OF FLAVOCOENZYMES - ANALYSIS OF RIBOFLAVIN SULFATES FROM SUGAR-BEET [J].
ABIAN, J ;
SUSIN, S ;
ABADIA, J ;
GELPI, E .
ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) :215-223
[2]   The ECHO technique -: the more effective way of data evaluation in liquid chromatography-tandem mass spectrometry analysis [J].
Alder, L ;
Lüderitz, S ;
Lindtner, K ;
Stan, HJ .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) :67-79
[3]  
ANG CYW, 1979, J ASSOC OFF ANA CHEM, V62, P1170
[4]  
[Anonymous], MODERN NUTR HLTH DIS
[5]   The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue [J].
Antignac, JP ;
de Wasch, K ;
Monteau, F ;
De Brabander, H ;
Andre, F ;
Le Bizec, B .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :129-136
[6]   Simple high-performance liquid chromatographic method for the determination of all seven vitamin B6 related compounds [J].
Argoudelis, CJ .
JOURNAL OF CHROMATOGRAPHY A, 1997, 790 (1-2) :83-91
[7]  
BAKER H, 1975, P49
[8]   An appraisal of vitamin B6 status indices and associated confounders, in young people aged 4-18 years and in people aged 65 years and over, in two national British surveys [J].
Bates, Christopher J. ;
Pentieva, Kristina D. ;
Prentice, Ann .
PUBLIC HEALTH NUTRITION, 1999, 2 (04) :529-535
[9]   A simple, sensitive and reproducible assay for pyridoxal 5′-phosphate and 4-pyridoxic acid in human plasma [J].
Bates, CJ ;
Pentieva, KD ;
Matthews, N ;
Macdonald, A .
CLINICA CHIMICA ACTA, 1999, 280 (1-2) :101-111
[10]   Vitamin analysis [J].
Bates, CJ .