Combining liquid chromatography with MALDI mass spectrometry using a heated droplet interface

被引:48
作者
Zhang, BY [1 ]
McDonald, C [1 ]
Li, L [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
D O I
10.1021/ac034934s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel interfacing technology is described to combine solution-based separation techniques such as liquid chromatography (LC) with matrix-assisted laser desorption ionization (MALDI) mass spectrometry. The interface includes a transfer tube having an inlet and an outlet, the inlet being adapted to accept the LC effluents and the outlet being adapted to form continuously replaced, hanging droplets of the liquid stream, and a MALDI sample plate mounted below the outlet of the transfer tube for collecting the droplets. The liquid stream in the transfer tube is heated to a temperature sufficient to cause partial evaporation of the carrier solvent from the hanging droplets. The droplets are dislodged to the MALDI plate, which is heated to above the boiling point of the carrier solvent to cause further evaporation of the carrier solvent from the collected droplets. It is found that analytes can be fractionated and deposited to a sample spot of 0.8 mm in diameter when a liquid flow rate of up to 50 muL/min and a fractionation interval of 1 min/spot are used. Flow rate of up to 200 muL/min can be used with a deposition sample spot of 2.4 mm in diameter on a commercial MALDI target. This heated droplet interface does not introduce sample loss, and the detection sensitivity of LC/MALDI is similar to that of standard MALDI, i.e., low femtomoles for peptide analysis with a microliter sample deposition. It is compatible with microbore and narrowbore column separation, thus allowing the injection of a larger amount of sample for separation and analysis, compared to a capillary column LC/MALDI system. The detection dynamic range is shown to be in the order of 106 for peptide mixture analysis, which is 4 orders of magnitude greater than standard MALDI. The application of this interface for combining LC with MALDI MS/MS is demonstrated in the proteome analysis of water-soluable protein components of E. coli K12 extracts.
引用
收藏
页码:992 / 1001
页数:10
相关论文
共 43 条
  • [1] BIEMANN K, 1998, Patent No. 57702782
  • [2] BIEMANN K, 1989, Patent No. 4843243
  • [3] MATRIX-ASSISTED LASER DESORPTION IONIZATION OF CAPILLARY ELECTROPHORESIS EFFLUENTS BY FOURIER-TRANSFORM MASS-SPECTROMETRY
    CASTORO, JA
    CHIU, RW
    MONNIG, CA
    WILKINS, CL
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (19) : 7571 - 7572
  • [4] Laser vaporization/ionization interface for capillary electrophoresis time-of-flight mass spectrometry
    Chang, SY
    Yeung, ES
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (13) : 2251 - 2257
  • [5] High-sensitivity peptide mapping by micro-LC with on-line membrane blotting and subsequent detection by scanning-IR-MALDI mass spectrometry
    Eckerskorn, C
    Strupat, K
    Kellermann, J
    Lottspeich, F
    Hillenkamp, F
    [J]. JOURNAL OF PROTEIN CHEMISTRY, 1997, 16 (05): : 349 - 362
  • [6] An automated noncontact deposition interface for liquid chromatography matrix-assisted laser desorption/ionization mass spectrometry
    Ericson, C
    Phung, QT
    Horn, DM
    Peters, EC
    Fitchett, JR
    Ficarro, SB
    Salomon, AR
    Brill, LM
    Brock, A
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2309 - 2315
  • [7] Aerosol MALDI with a reflectron time-of-flight mass spectrometer
    Fei, X
    Wei, G
    Murray, KK
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (07) : 1143 - 1147
  • [8] Quantitative proteomic analysis using a MALDI quadrupole time-of-flight mass spectrometer
    Griffin, TJ
    Gygi, SP
    Rist, B
    Aebersold, R
    Loboda, A
    Jilkine, A
    Ens, W
    Standing, KG
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (05) : 978 - 986
  • [9] CONTINUOUS-FLOW MALDI MASS-SPECTROMETRY USING AN ION-TRAP REFLECTION TIME-OF-FLIGHT DETECTOR
    HE, L
    LIANG, L
    LUBMAN, DM
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (22) : 4127 - 4132
  • [10] Kassis CE, 1997, RAPID COMMUN MASS SP, V11, P1134, DOI 10.1002/(SICI)1097-0231(19970630)11:10<1134::AID-RCM910>3.0.CO