Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis

被引:96
作者
Mitarai, S. [1 ]
Okumura, M. [2 ]
Toyota, E. [3 ]
Yoshiyama, T. [2 ]
Aono, A. [4 ]
Sejimo, A. [5 ]
Azuma, Y. [4 ]
Sugahara, K. [5 ]
Nagasawa, T. [5 ]
Nagayama, N. [3 ]
Yamane, A. [3 ]
Yano, R. [2 ]
Kokuto, H. [2 ]
Morimoto, K. [2 ]
Ueyama, M. [2 ]
Kubota, M. [2 ]
Yi, R. [2 ]
Ogata, H. [2 ]
Kudoh, S. [2 ]
Mori, T. [1 ]
机构
[1] JATA, Res Inst TB, Bacteriol Div, Dept Mycobacterium Reference & Res, Tokyo 2048533, Japan
[2] JATA, Double Barred Cross Hosp, Dept Resp & Internal Med, Tokyo 2048533, Japan
[3] Tokyo Hosp, Natl Hosp Org, Dept Resp & Internal Med, Tokyo, Japan
[4] JATA, Double Barred Cross Hosp, Microbiol Lab, Tokyo 2048533, Japan
[5] Tokyo Hosp, Natl Hosp Org, Microbiol Lab, Tokyo, Japan
关键词
LAMP; tuberculosis; diagnosis; POLYMERASE-CHAIN-REACTION; HUMAN-IMMUNODEFICIENCY-VIRUS; MYCOBACTERIA DIRECT ASSAY; PULMONARY TUBERCULOSIS; RESPIRATORY SPECIMENS; CLINICAL-EVALUATION; SPUTUM SAMPLES; RIFAMPIN RESISTANCE; DEVELOPING-COUNTRY; AMPLICOR MTB;
D O I
10.5588/ijtld.10.0629
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
OBJECTIVE: A new loop-mediated isothermal amplification (LAMP) test kit, including a simple DNA extraction device for the detection of Mycobacterium tuberculosis complex, was developed for commercial use and evaluated for its usefulness in diagnosing tuberculosis (TB). DESIGN: The LAMP test was performed using untreated and N-acetyl-L-cysteine (NALC) NaOH-treated sputum specimen. The efficiency of the kit was compared with other conventional laboratory examinations, including other nucleic acid amplification (NAA) tests. RESULTS: The sensitivity of LAMP using raw sputum (direct LAMP) in smear- and culture-positive specimens was 98.2% (95% CI 94.9-99.4), while the sensitivity in smear-negative, culture-positive specimens was 55.6% (95% CI 43.4-68.0). The diagnostic sensitivity of direct LAMP for the diagnosis of individuals with TB was 88.2% (95% CI 81.4-92.7). The sensitivity values of direct LAMP were slightly, but not statistically significantly lower than those of Cobas Amplicor MTB and TRC Rapid MT, while the sensitivity of the LAMP test using NALC-NaOH treated sputum was significantly lower than other NAA tests (P < 0.05) for smear-negative, culture-positive specimens. The new commercial version of the LAMP kit was easy to handle and yielded results within 1 h of receiving sputum specimens. CONCLUSIONS: This test is considered a promising diagnostic tool for TB, even for peripheral laboratories with limited equipment, such as those in developing countries.
引用
收藏
页码:1211 / 1217
页数:7
相关论文
共 38 条
  • [1] Adhikari BR, 2009, JPN J INFECT DIS, V62, P212
  • [2] [Anonymous], 2008, WHO/HTM/TB/2008.394
  • [3] An evaluation of the BD ProbeTec ET system for the direct detection of Mycobacterium tuberculosis in respiratory samples
    Barrett, A
    Magee, JG
    Freeman, R
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2002, 51 (10) : 895 - 898
  • [4] EVALUATION OF AMPLICOR PCM FOR DIRECT-DETECTION OF MYCOBACTERIUM-TUBERCULOSIS FROM SPUTUM SPECIMENS
    BEAVIS, KG
    LICHTY, MB
    JUNGKIND, DL
    GIGER, O
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (10) : 2582 - 2586
  • [5] Clinical evaluation of the roche AMPLICOR PCR Mycobacterium tuberculosis test for detection of M-tuberculosis in respiratory specimens
    Bergmann, JS
    Woods, GL
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (05) : 1083 - 1085
  • [6] Clinical evaluation of the BDProbeTec ET system for rapid detection of Mycobacterium tuberculosis
    Bergmann, JS
    Keating, WE
    Woods, GL
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (02) : 863 - 865
  • [7] Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries
    Boehme, Catharina C.
    Nabeta, Pamela
    Henostroza, German
    Raqib, Rubhana
    Rahim, Zeaur
    Gerhardt, Martina
    Sanga, Erica
    Hoelscher, Michael
    Notomi, Tsugunori
    Hase, Tetsu
    Perkins, Mark D.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (06) : 1936 - 1940
  • [8] Rapid Molecular Detection of Tuberculosis and Rifampin Resistance
    Boehme, Catharina C.
    Nabeta, Pamela
    Hillemann, Doris
    Nicol, Mark P.
    Shenai, Shubhada
    Krapp, Fiorella
    Allen, Jenny
    Tahirli, Rasim
    Blakemore, Robert
    Rustomjee, Roxana
    Milovic, Ana
    Jones, Martin
    O'Brien, Sean M.
    Persing, David H.
    Ruesch-Gerdes, Sabine
    Gotuzzo, Eduardo
    Rodrigues, Camilla
    Alland, David
    Perkins, Mark D.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (11) : 1005 - 1015
  • [9] CLINICAL UTILITY OF A COMMERCIAL TEST BASED ON THE POLYMERASE CHAIN-REACTION FOR DETECTING MYCOBACTERIUM-TUBERCULOSIS IN RESPIRATORY SPECIMENS
    CHIN, DP
    YAJKO, DM
    HADLEY, WK
    SANDERS, CA
    NASSOS, PS
    MADEJ, JJ
    HOPEWELL, PC
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (06) : 1872 - 1877
  • [10] Current issues on molecular and immunological diagnosis of tuberculosis
    Cho, Sang-Nae
    [J]. YONSEI MEDICAL JOURNAL, 2007, 48 (03) : 347 - 359