Rapid and selective determination of UV filters in seawater by liquid chromatography-tandem mass spectrometry combined with stir bar sorptive extraction

被引:65
作者
Nguyen, Kieu T. N. [1 ]
Scapolla, Carlo [1 ]
Di Carro, Marina [1 ]
Magi, Emanuele [1 ]
机构
[1] Univ Genoa, Dept Chem & Ind Chem, I-16146 Genoa, Italy
关键词
Liquid chromatography-tandem mass spectrometry (LC-MS/MS); Electrospray; Atmospheric pressure chemical ionization; Stir bar sorptive extraction-liquid desorption (SBSE-LD); UV filters; Seawater; PRESSURE CHEMICAL-IONIZATION; ELECTROSPRAY-IONIZATION; WATER SAMPLES; MICROEXTRACTION; OPTIMIZATION; BIOCIDES; SLUDGE; MS;
D O I
10.1016/j.talanta.2011.07.085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fast liquid chromatography coupled to triple-quadrupole tandem mass spectrometry was employed for the determination of six UV filters in seawater. The separation of the analytes was achieved in less than 5 min; polarity switching was used as four of the analytes were ionized in positive mode and the remaining two in negative mode. Two ionization sources were employed and compared: atmospheric pressure chemical ionization (APCI) gave better results than electrospray ionization (ESI) for all analytes, with higher reproducibility and lower detection limits. Therefore APCI was chosen for the determination of the analytes in seawater samples using stir bar sorptive extraction-liquid desorption (SBSE-LD). Quantitative analysis was performed in multiple reaction monitoring (MRM) mode; fragmentation pathways of the analytes with regard to the formation of the MRM ions were also proposed. For the analysis of seawater samples, calibration curves were drawn using SBSE in spiked seawater. All figures of merit of the method were satisfactory; limits of detection were particularly low for the four analytes ionized in positive mode, being in the range 8-31 ng/L. The method was applied to the determination of the six UV filters in seawater samples from Liguria, Italy. Only benzophenone-3 (BP-3) and ethylhexyl methoxycinnamate (EHMC) were measured in the analyzed samples; some of the remaining analytes were also detected but always below the limit of quantitation. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2375 / 2384
页数:10
相关论文
共 40 条
[1]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[2]  
2-4
[3]  
Barcelo Damia., 1996, APPL LC MS ENV CHEM
[4]   Analysis of cyanoacrylate ultraviolet absorbers using liquid chromatography/atmospheric pressure chemical ionization mass spectrometry: influence of fragmentor voltage and solvent on ionization and fragmentation behaviors [J].
Choi, Sung-Seen ;
Song, Min Ju .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (16) :2580-2586
[5]  
Dass C., 2007, FUNDAMENTALS CONT MA, P46
[6]   Stir bar sorptive extraction for trace analysis [J].
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :54-69
[7]   Widespread occurrence of estrogenic UV-filters in aquatic ecosystems in Switzerland [J].
Fent, Karl ;
Zenker, Armin ;
Rapp, Maja .
ENVIRONMENTAL POLLUTION, 2010, 158 (05) :1817-1824
[8]   Determination of organic UV filters in water by stir bar sorptive extraction and direct analysis in real-time mass spectrometry [J].
Haunschmidt, Manuela ;
Klampfl, Christian W. ;
Buchberger, Wolfgang ;
Hertsens, Robert .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (01) :269-275
[9]  
Hoffmann E.d., 2007, MASS SPECTROMETRY PR, V3, P43
[10]   Novel stir bar sorptive extraction methods for environmental and biomedical analysis [J].
Kawaguchi, M ;
Ito, R ;
Saito, K ;
Nakazawa, H .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (03) :500-508