Characterization of porous hydroxyapatite

被引:302
作者
Hing, KA [1 ]
Best, SM [1 ]
Bonfield, W [1 ]
机构
[1] Univ London Queen Mary & Westfield Coll, IRC Biomed Mat, London E1 4NS, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1023/A:1008929305897
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hydroxyapatite has been considered for use in the repair of osseous defects for the last 20 years. Recent developments have led to interest in the potential of porous hydroxyapatite as a synthetic bone graft. However, despite considerable activity in this field, regarding assessment of the biological response to such materials, the basic materials characterization is often inadequate. This paper documents the characterization of the chemical composition, mechanical integrity, macro- and microstructure of a porous hydroxyapatite, Endobon(R) (E. Merck GmbH), intended for the bone-graft market. Specimens possesed a range of apparent densities from 0.35 to 1.44 g cm(-3). Chemical analysis demonstrated that the natural apatite precursor of Endobon(R) was not converted to pure hydroxyapatite, but retained many of the ionic substituents found in bone mineral, notably carbonate, sodium and magnesium ions. Investigation of the microstructure illustrated that the struts of the material were not fully dense, but had retained some traces of the network of osteocyte lacunae. Macrostructural analysis demonstrated the complex inter-relationship between the structural features of an open pore structure. Both pore size and connectivity were found to be inversely dependent on apparent density. Furthermore, measurement of pore aspect ratio and orientation demonstrated a relationship between apparent density and the degree of macrostructural anisotropy within the specimens, while, it was also noted that pore connectivity was sensitive to anisotropy. Compression testing demonstrated the effect of apparent density and macrostructural anisotropy on the mechanical properties. An increase in apparent density from 0.38 to 1.25 g cm(-3) resulted in increases in ultimate compressive stress and compressive modulus of 1 to 11 MPa and 0.2 to 3.1 GPa, respectively. Furthermore, anisotropic high density (> 0.9 g cm(-3)) specimens were found to possess lower compressive moduli than isotropic specimens with equivalent apparent densities. These results underline the importance of full structural and mechanical characterization of porous ceramic implant materials. (C) 1999 Kluwer Academic Publishers.
引用
收藏
页码:135 / 145
页数:11
相关论文
共 40 条
  • [1] EFFECTS OF SINTERING CONDITIONS ON HYDROXYAPATITE FOR USE IN MEDICAL APPLICATIONS - A POWDER DIFFRACTION STUDY
    ABRAHAMS, I
    KNOWLES, JC
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 1994, 4 (02) : 185 - 188
  • [2] Aoki H., 1991, SCI MED APPL HYDROXY
  • [3] BARRALET J, 1995, THESIS U LONDON
  • [4] The dependence of osteoblastic response on variations in the chemical composition and physical properties of hydroxyapatite
    Best, S
    Sim, B
    Kayser, M
    Downes, S
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (02) : 97 - 103
  • [5] INVITRO MODEL OF ALUMINUM-INDUCED OSTEOMALACIA - INHIBITION OF HYDROXYAPATITE FORMATION AND GROWTH
    BLUMENTHAL, NC
    POSNER, AS
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1984, 36 (04) : 439 - 441
  • [6] BLUMENTHAL NC, 1992, MATER RES SOC SYMP P, V252, P29
  • [7] CURREY JD, 1970, CLIN ORTHOP RELAT R, P210
  • [8] DEBRUIJN JD, 1993, THESIS U LEIDEN
  • [9] Denissen HW., 1980, SCI CERAM, V10, P63
  • [10] DEWITH G, 1981, J MATER SCI, V16, P1592, DOI 10.1007/BF02396876