Duplex ultrasound for assessment of superior mesenteric artery blood flow

被引:85
作者
Perko, MJ
机构
[1] Univ Copenhagen, Rigshosp, Dept Vasc Surg, Copenhagen, Denmark
[2] Univ Copenhagen, Rigshosp, Dept Cardiothorac Surg, Copenhagen, Denmark
关键词
mesenteric circulation; mesenteric physiology; mesenteric surgery; ultrasonics;
D O I
10.1053/ejvs.2001.1313
中图分类号
R61 [外科手术学];
学科分类号
摘要
Duplex ultrasound (DU) is recognised as a valuable tool for the assessment of blood flow in many vascular territories. The application of this technique to the superior mesenteric artery (SMA) has increased vapidly throughout the last decade. The purpose of this review is to collate currently available information on the utility of SMA DU, both in terms of research and clinical practice. Research investigations have revealed low intra- and interobserver variability in the estimation of Doppler variables, while reliable evaluation of B-mode dimensions requires repeated measurements. SMA blood flow velocity has been found to be dependent upon changes in central haemodynamics and in peripheral resistance, which was documented in studies with hypotension, medication and post-prandially. Food intake induces mesenteric vasorelaxation reflected by a 10-fold increase in the diastolic velocity. This feature has been utilised in studies on mesenteric physiology which confirmed parasympathetic activity during hypovolaemia, and showed that exercise increases splanchnic resistance and reduces its blood flow following a 50% reduction in the hepato-splenic and a 25% reduction in the mesenteric blood flow. Clinical studies have documented high sensitivity and specificity of DU in detection of disease in splanchnic arteries. Diastolic velocity was found to be the most accurate indicator of SMA stenosis, while an absent Doppler signal from a well visualised vessel has been found to be a reliable predictor of occlusion. The high predictive value of DU in the detection of mesenteric artery disease, together with its simplicity and non-invasiveness, suggests that DU should take precedence over arteriography in both clinical practice and laboratory investigations.
引用
收藏
页码:106 / 117
页数:12
相关论文
共 95 条
[1]   INCREASED FLOW IN THE SUPERIOR MESENTERIC-ARTERY IN DUMPING SYNDROME [J].
ALDOORI, MI ;
QAMAR, MI ;
READ, AE ;
WILLIAMSON, RCN .
BRITISH JOURNAL OF SURGERY, 1985, 72 (05) :389-390
[2]   Doppler ultrasonographic evaluation of splanchnic blood flow in coeliac disease [J].
Arienti, V ;
Califano, C ;
Brusco, G ;
Boriani, L ;
Biagi, F ;
Sama, MG ;
Sottili, S ;
Domanico, A ;
Corazza, GR ;
Gasbarrini, G .
GUT, 1996, 39 (03) :369-373
[3]  
BELVAN F, 1990, RADIOLOGY, V174, P165
[4]   DUPLEX ULTRASONOGRAPHY IN THE DIAGNOSIS OF CELIAC AND MESENTERIC-ARTERY OCCLUSIVE DISEASE [J].
BOWERSOX, JC ;
ZWOLAK, RM ;
WALSH, DB ;
SCHNEIDER, JR ;
MUSSON, A ;
LABOMBARD, FE ;
CRONENWETT, JL .
JOURNAL OF VASCULAR SURGERY, 1991, 14 (06) :780-788
[5]   SPLANCHNIC HEMODYNAMIC-CHANGES DURING ACUTE HYPOGLYCEMIA IN MAN [J].
BRAATVEDT, GD ;
NEWRICK, PG ;
HALLIWELL, M ;
WELLS, PNT ;
READ, AE ;
CORRALL, RJM .
CLINICAL SCIENCE, 1991, 81 (04) :519-524
[6]   SPLANCHNIC BLOOD-FLOW IN MAN - EVIDENCE FOR MEDIATION VIA A BETA-ADRENERGIC MECHANISM [J].
BRAATVEDT, GD ;
FLYNN, MD ;
STANNERS, A ;
HALLIWELL, M ;
CORRALL, RJM .
CLINICAL SCIENCE, 1993, 84 (02) :201-207
[7]  
BURNS PN, 1988, CLIN APPLICATIONS DO, P76
[8]   Power versus conventional color Doppler sonography: Comparison in the depiction of vasculature in liver tumors [J].
Choi, BI ;
Kim, TK ;
Han, JK ;
Chung, JW ;
Park, JH ;
Han, MC .
RADIOLOGY, 1996, 200 (01) :55-58
[9]   SUPERIOR MESENTERIC ANGIOGRAPHY AND BLOOD-FLOW MEASUREMENT FOLLOWING INTRA-ARTERIAL INJECTION OF PROSTAGLANDIN-E1 [J].
CLARK, RA ;
COLLEY, DP ;
JACOBSON, ED ;
HERMAN, R ;
TYLER, G ;
STAHL, D .
RADIOLOGY, 1980, 134 (02) :327-333
[10]   FASTING AND POSTPRANDIAL SPLANCHNIC BLOOD-FLOW IS REDUCED BY A SOMATOSTATIN ANALOG (OCTREOTIDE) IN MAN [J].
COOPER, AM ;
BRAATVEDT, GD ;
QAMAR, MI ;
BROWN, H ;
THOMAS, DM ;
HALLIWELL, M ;
READ, AE ;
CORRALL, RJM .
CLINICAL SCIENCE, 1991, 81 (02) :169-175