Sample stacking with matrix removal for the determination of paraquat, diquat and difenzoquat in water by capillary electrophoresis

被引:60
作者
Núñez, O [1 ]
Moyano, E [1 ]
Puignou, L [1 ]
Galceran, MT [1 ]
机构
[1] Univ Barcelona, Fac Quim, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
water analysis; sample stacking; sample handling; quaternary ammonium herbicides; pesticides;
D O I
10.1016/S0021-9673(01)00582-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conditions for the simultaneous determination of paraquat, diquat and difenzoquat by capillary zone electrophoresis using a stacking technique in a chemically modified capillary have been established. To apply the stacking method with sample matrix removal for the analysis of cations, an anodic electroosmotic flow is mandatory. For quats, 50 mM acetic acid-ammonium acetate (pH 4.0) with 5% (v/v) methanol as electrophoretic buffer and the addition of 0.8 mM cetyltrimethylammonium bromide as wall capillary organic modifier was proposed. Field polarity reversal time was optimised fur several sample matrices. Detection was carried out at 220 and 255 nm. Detection limits, based on a signal-to-noise ratio of 3:1, were lower than 15 mug 1(-1) for standards in Milli-Q water and two to ten times higher for drinking water samples. Run-to-run and day-to-day reproducibility have been established. The method was successfully applied to the determination of the three herbicides in spiked drinking water. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 37 条
[1]  
ALBIN M, 1993, ANAL CHEM, V65, P489
[2]   ENVIRONMENTAL-PROTECTION-AGENCY AND OTHER METHODS FOR THE DETERMINATION OF PRIORITY PESTICIDES AND THEIR TRANSFORMATION PRODUCTS IN WATER [J].
BARCELO, D .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :117-143
[3]   Electrochemical detection of herbicides and plant growth regulators at membrane glassy carbon electrodes [J].
Bianco, P ;
Aghroud, N .
ELECTROANALYSIS, 1997, 9 (08) :602-607
[4]  
*BRIT CROP PROT CO, 1994, PEST MAN WORLD COMP
[5]   CAPILLARY ZONE ELECTROPHORESIS OF 2 CATIONIC HERBICIDES, PARAQUAT AND DIQUAT [J].
CAI, JY ;
ELRASSI, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (6-7) :1193-1200
[6]   RAPID METHOD FOR SIMULTANEOUS DETERMINATION OF PARAQUAT AND DIQUAT IN POND AND RIVER WATERS BY PYROLYSIS AND GAS-CHROMATOGRAPHY [J].
CANNARD, AJ ;
CRIDDLE, WJ .
ANALYST, 1975, 100 (1197) :848-853
[7]   COMPARISON OF CAPILLARY ELECTROPHORESIS AND REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF PARAQUAT, DIQUAT AND DIFENZOQUAT [J].
CARNEIRO, MC ;
PUIGNOU, L ;
GALCERAN, MT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :217-224
[8]  
CARNEIRO MC, 1996, THESIS U BARCELONA B
[9]   Ion-pair liquid chromatography atmospheric pressure ionization mass spectrometry for the determination of quaternary ammonium herbicides [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (01) :145-154
[10]   On-line ion-pair solid-phase extraction-liquid chromatography-mass spectrometry for the analysis of quaternary ammonium herbicides [J].
Castro, R ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :441-449