Analysis of initial CT findings after endovascular repair of abdominal aortic aneurysm

被引:23
作者
Sawhney, R
Kerlan, RK
Wall, SD
Chuter, TAM
Ruiz, DE
Canto, CJ
LaBerge, JM
Reilly, LM
Yee, J
Wilson, MW
Jean-Claude, J
Faruqi, RM
Gordon, RL
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Surg, San Francisco, CA 94143 USA
关键词
aneurysm; abdominal; aortic; aorta; CT; grafts and prostheses; interventional procedures; complications;
D O I
10.1148/radiology.220.1.r01jl22157
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the spectrum and frequency of specific computed tomographic (CT) findings in the acute period after endovascular repair of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: CT images obtained 1-3 days after endograft placement were evaluated in 88 patients. The images were analyzed for stent position, appearance of endograft components, perigraft leak, and postoperative findings including air and acute thrombus within the aneurysm and air surrounding the femoral-femoral bypass graft. Findings that could be misinterpreted as perigraft leak were evaluated. RESULTS: Fifteen (17%) of 88 patients had perigraft leak in the acute postoperative period. The bare segment of the proximal self-expanding stent covered one or both renal arteries in 54 (61%) patients. One patient had CT evidence of renovascular compromise. Postoperative air was within the aneurysmal sac in 51 (58%) patients and surrounded the femoral-femoral bypass graft in 67 (94%) of 71 patients in whom the grafts were evaluated with CT. Mottled attenuation within the aneurysmal sac was seen in 50 (57%) patients. Forty-six (52%) patients had calcifications within longstanding thrombus. In 31 (35%) patients, findings that could have been misinterpreted as perigraft leak were identified. CONCLUSION: Accurate analysis of CT findings after endovascular AAA repair requires careful review of all available CT images (preprocedural and pre- and postcontrast) and clear understanding of specific stent-graft components and placement.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 20 条
[1]   Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[2]   Abdominal aortic aneurysms: Preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts [J].
Blum, U ;
Langer, M ;
Spillner, G ;
Mialhe, C ;
Beyersdorf, F ;
BuitragoTellez, C ;
Voshage, G ;
Duber, C ;
Schlosser, V ;
Cragg, AH .
RADIOLOGY, 1996, 198 (01) :25-31
[3]   Abdominal aortic aneurysm in high-risk patients: Short- to intermediate-term results of endovascular repair [J].
Chuter, TAM ;
Gordon, RL ;
Reilly, LM ;
Kerlan, RK ;
Sawhney, R ;
Jean-Claude, J ;
Canto, CJ ;
LaBerge, JM ;
Ring, EJ ;
Wall, SD ;
Messina, LM .
RADIOLOGY, 1999, 210 (02) :361-365
[4]   Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair [J].
Chuter, TAM ;
Risberg, B ;
Hopkinson, BR ;
Wendt, G ;
Scott, RAP ;
Walker, PJ ;
Viscomi, S ;
White, G .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (04) :655-666
[5]   Treatment of abdominal aortic aneurysms with transfemoral placement of stent-grafts: Complications and secondary radiologic intervention [J].
Dorffner, R ;
Thurnher, S ;
Polterauer, P ;
Kretschmer, G ;
Lammer, J .
RADIOLOGY, 1997, 204 (01) :79-86
[6]   Abdominal aortic aneurysms: Treatment with juxtarenal placement of covered stent-grafts [J].
Duda, SH ;
Raygrotzki, S ;
Wiskirchen, J ;
Khalighi, K ;
Schott, U ;
Bares, R ;
Ziemer, G ;
Claussen, CD .
RADIOLOGY, 1998, 206 (01) :195-198
[7]   Helical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition [J].
Golzarian, J ;
Dussaussois, L ;
Abada, HT ;
Gevenois, PA ;
Van Gansbeke, D ;
Ferreira, J ;
Struyven, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) :329-331
[8]   Endovascular aortic stent-grafts: Transcatheter embolization of persistent perigraft leaks [J].
Golzarian, J ;
Struyven, J ;
Abada, HT ;
Wery, D ;
Dussaussois, L ;
Madani, A ;
Ferreira, J ;
Dereume, JP .
RADIOLOGY, 1997, 202 (03) :731-734
[9]   Endovascular management of "endoleaks" after transluminal infrarenal abdominal aneurysm repair [J].
Holzenbein, TJ ;
Kretschmer, G ;
Dorffner, R ;
Thurnher, S ;
Sandner, D ;
Minar, E ;
Lammer, J ;
Polterauer, P .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 16 (03) :208-217
[10]   Treatment of aortoiliac aneurysms with use of single-piece tapered stent-grafts [J].
Kato, N ;
Dake, MD ;
Semba, CP ;
Razavi, MK ;
Kee, ST ;
Slonim, SM ;
Samuels, SLW ;
Terasaki, KK ;
Zarins, CK ;
Mitchell, RS ;
Miller, DC .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) :41-49