Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes

被引:678
作者
Ricci, F [1 ]
Palleschi, G [1 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
关键词
Prussian Blue; modified electrodes; review; biosensor; hexacyanoferrate;
D O I
10.1016/j.bios.2004.12.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Being one of the most commonly used electrochemical mediators for analytical applications, Prussian Blue has found a wide use in the biosensor field during the last years. Its particular characteristic of catalysing hydrogen peroxide reduction has been applied in the construction of a large number of oxidase enzyme-based biosensors for clinical, environmental and food analysis. By modifying an electrode surface with Prussian Blue, it is in fact possible to easily detect hydrogen peroxide at an applied potential around 0.0 V versus Ag/AgCl, thus making possible coupling with oxidase enzymes while also avoiding or reducing electrochemical interferences. Papers dealing with glucose, lactate, cholesterol and galactose biosensors that are based on the use of Prussian Blue have recently appeared in the most important analytical chemistry journals. Another recent trend is the use of a choline probe based on choline oxidase for pesticide determination to exploit the inhibition of acetylcholinesterase by these compounds. In addition, the use of Prussian Blue in the development of biosensors for food analysis has captured the interest of many research groups and led to improved methods for the detection of glutamate, galactose, alcohol, fructosyl amine, formate, lysine and oxalate. This review will focus on the biosensing aspects of Prussian Blue-based sensors giving a general overview of the advantages provided by such mediator as well as its drawbacks. A comprehensive bibliographic reference list is presented together with the most up to date research findings in this field and possible future applications. The commercial potential of sensors based on this mediator will also be discussed. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:389 / 407
页数:19
相关论文
共 147 条
[1]   Configurations used in the design of screen-printed enzymatic biosensors.: A review [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) :153-163
[2]   VOLTAMMETRIC BEHAVIOR OF PERBORATE ON PRUSSIAN-BLUE-MODIFIED CARBON PASTE ELECTRODES [J].
BOYER, A ;
KALCHER, K ;
PIETSCH, R .
ELECTROANALYSIS, 1990, 2 (02) :155-161
[3]   CRYSTAL-STRUCTURE OF PRUSSIAN BLUE - FE4[FE(CN)6]3.XH2O [J].
BUSER, HJ ;
SCHWARZENBACH, D ;
PETTER, W ;
LUDI, A .
INORGANIC CHEMISTRY, 1977, 16 (11) :2704-2710
[4]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[5]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[6]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[7]   Estimation of soluble L-lactate in dairy products using screen-printed sensors in a flow injection analyser [J].
Collier, WA ;
Lovejoy, P ;
Hart, AL .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :219-225
[8]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[9]   PEROXIDASE-MODIFIED CARBON-FIBER MICROELECTRODES IN FLOW-THROUGH DETECTION OF HYDROGEN-PEROXIDE AND ORGANIC PEROXIDES [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G ;
TUDOS, AJ ;
KOK, WT .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3604-3610
[10]   VALENCE DELOCALIZATION IN PRUSSIAN BLUE FE4III[FEII(CN)6]3.XD2O, BY POLARIZED NEUTRON-DIFFRACTION [J].
DAY, P ;
HERREN, F ;
LUDI, A ;
GUDEL, HU ;
HULLIGER, F ;
GIVORD, D .
HELVETICA CHIMICA ACTA, 1980, 63 (01) :148-153