Respiratory mechanics and lung histology in normal rats anesthetized with sevoflurane

被引:21
作者
Correa, FCF
Ciminelli, PB
Falcao, H
Alcântara, BJC
Contador, RS
Medeiros, AS
Zin, WA
Rocco, PRM [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Biofis Carlos Chagas Filho, Physiol Resp Lab, Ctr Ciencias Saude, BR-21949900 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Fac Med, BR-21949900 Rio De Janeiro, Brazil
关键词
tissue resistance; viscoelasticity; lung morphometry; elastance;
D O I
10.1152/jappl.2001.91.2.803
中图分类号
Q4 [生理学];
学科分类号
071003 [生理学];
摘要
Respiratory system, lung, and chest wall mechanical properties were subdivided into their resistive, elastic, and viscoelastic/inhomogeneous components in normal rats, to define the sites of action of sevoflurane. In addition, we aimed to determine the extent to which pretreatment with atropine modified these parameters. Twenty-four rats were divided into four groups of six animals each: in the P group, rats were sedated (diazepam) and anesthetized with pentobarbital sodium; in the S group, sevoflurane was administered; in the AP and AS groups, atropine was injected 20 min before sedation/anesthesia with pentobarbital and sevoflurane, respectively. Sevoflurane increased lung viscoelastic/inhomogeneous pressures and static elastance compared with rats belonging to the P group. In AS rats, lung static elastance increased in relation to the AP group. In conclusion, sevoflurane anesthesia acted not at the airway level but at the lung periphery, stiffening lung tissues and increasing mechanical inhomogeneities. These findings were supported by the histological demonstration of increased areas of alveolar collapse and hyperinflation. The pretreatment with atropine reduced central and peripheral airway secretion, thus lessening lung inhomogeneities.
引用
收藏
页码:803 / 810
页数:8
相关论文
共 43 条
[1]
Airway-parenchymal interdependence after airway contraction in rat lung explants [J].
Adler, A ;
Cowley, EA ;
Bates, JH ;
Eidelman, DH .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (01) :231-237
[2]
COMPARATIVE FEATURES OF THE MECHANICS OF BREATHING [J].
AGOSTONI, E ;
THIMM, FF ;
FENN, WO .
JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (05) :679-683
[3]
RESPIRATORY MECHANICS IN THE NORMAL DOG DETERMINED BY EXPIRATORY FLOW INTERRUPTION [J].
BATES, JHT ;
BROWN, KA ;
KOCHI, T .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (06) :2276-2285
[4]
EFFECT OF VALVE CLOSURE TIME ON THE DETERMINATION OF RESPIRATORY RESISTANCE BY FLOW INTERRUPTION [J].
BATES, JHT ;
HUNTER, IW ;
SLY, PD ;
OKUBO, S ;
FILIATRAULT, S ;
MILICEMILI, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (02) :136-140
[5]
ANALYSIS OF THE BEHAVIOR OF THE RESPIRATORY SYSTEM WITH CONSTANT INSPIRATORY FLOW [J].
BATES, JHT ;
ROSSI, A ;
MILICEMILI, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (06) :1840-1848
[6]
INTERRUPTER RESISTANCE ELUCIDATED BY ALVEOLAR PRESSURE MEASUREMENT IN OPEN-CHEST NORMAL DOGS [J].
BATES, JHT ;
LUDWIG, MS ;
SLY, PD ;
BROWN, K ;
MARTIN, JG ;
FREDBERG, JJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (01) :408-414
[7]
A THEORETICAL-ANALYSIS OF INTERRUPTER TECHNIQUE FOR MEASURING RESPIRATORY MECHANICS [J].
BATES, JHT ;
BACONNIER, P ;
MILICEMILI, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (05) :2204-2214
[8]
BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
[9]
BERNSTINE ML, 1957, ANESTHESIOLOGY, V18, P866
[10]
FLUID DYNAMIC FACTORS IN TRACHEAL PRESSURE MEASUREMENT [J].
CHANG, HK ;
MORTOLA, JP .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (01) :218-225