Determination of cadmium in hair and blood by tungsten coil electrothermal atomic absorption spectrometry with chemical modifiers

被引:28
作者
Bruhn, CG
Neira, JY
Valenzuela, GD
Nóbrega, JA
机构
[1] Univ Concepcion, Fac Farm, Dept Anal Instrumental, Concepcion, Chile
[2] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
关键词
chemical modifiers; tungsten coil electrothermal atomizer; cadmium; hair; blood;
D O I
10.1016/S0039-9140(98)00276-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three chemical modifiers ((NH(4))(2)HPO(4), NH(4)H(2)PO(4), and Pd as Pd(NO(3))(2)) were evaluated for the determination of Cd in acid-digested solutions of hair and blood using electrothermal atomic absorption spectrometry in a tungsten coil atomizer (TCA). All modifiers caused some thermal stabilization of Cd when compared to the behavior observed in nitric acid medium. The best effects were observed in 15 mu g ml(-1) Pd medium; the characteristic mass of Cd was 0.3 pg and the method detection limits were 0.009 mu g g(-1) in hair and 0.2 mu g l(-1) in blood. In addition to a slight thermal stabilization effect, Pd also increased the sensitivity for Cd by ca. 40% and the tungsten coil lifetime by 20% (i.e. from 300 to 360 heating cycles), reduced background signals, and eliminated condensed phase interferences caused by concomitants. The accuracy (3.2% as mean relative error in the Pd modifier) was checked for the determination of Cd in acid-digested solutions of certified reference materials of human hair and blood and by recoveries of Cd in spiked hair and blood samples by both TCA and a graphite furnace procedure. All results obtained in chemical modifiers are in agreement at a 95% confidence level. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:537 / 549
页数:13
相关论文
共 31 条
[1]  
ATNASHEV VB, 1982, ZH ANAL KHIM, V37, P1590
[2]  
ATNASHEV YB, 1985, ZH PRIKL SPEKTROSK, V42, P537
[3]   SIMPLE LOW-COST TUNGSTEN-COIL ATOMIZER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERNDT, H ;
SCHALDACH, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :709-712
[4]  
BRUHN C, 1981, ANAL CHIM ACTA, V130, P209, DOI 10.1016/S0003-2670(01)84167-2
[5]   ANALYTICAL EVALUATION OF A TUNGSTEN COIL ATOMIZER FOR CADMIUM, LEAD, CHROMIUM, MANGANESE, NICKEL AND COBALT DETERMINATION BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUHN, CG ;
AMBIADO, FE ;
CID, HJ ;
WOERNER, R ;
TAPIA, J ;
GARCIA, R .
ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) :183-192
[6]  
Bruhn CG, 1996, QUIM ANAL, V15, P191
[7]   Chemical modifiers in a tungsten coil electrothermal atomizer. Part 1. Determination of lead in hair and blood [J].
Bruhn, CG ;
Neira, JY ;
Valenzuela, GD ;
Nobrega, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (01) :29-35
[8]  
BRUHN CG, 1994, J ANAL ATOM SPECTROM, V9, P531
[9]   ULTRAMICRO ATOMIC-ABSORPTION SPECTROSCOPY WITH A TUNGSTEN-FILAMENT ATOM-RESERVOIR [J].
CANTLE, JE ;
WEST, TS .
TALANTA, 1973, 20 (05) :459-467
[10]  
CHATT A, 1988, APPL BIOMEDICAL ENV