Comparison of some analytical performance characteristics in inductively coupled plasma spectrometry of platinum group metals and gold

被引:20
作者
Kanicky, V [1 ]
Otruba, V
Mermet, JM
机构
[1] Masaryk Univ, Dept Analyt Chem, CZ-61137 Brno, Czech Republic
[2] Univ Lyon 1, Sci Analyt Lab, UMR 5619, F-69622 Villeurbanne, France
关键词
platinum group metals; inductively coupled plasma spectrometry; ion associates; surfactants;
D O I
10.1016/S0039-9140(98)00102-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The limits of detection, precision and matrix effects in the inductively coupled plasma spectrometry of platinum group metals (PGMs) and gold were measured and evaluated for four ICP-AES and one ICP-MS instrument. The sample matrix was a cationic surfactant used for the PGMs and gold preconcentration on a modified silica gel (C18). A sorption of ion associates of PGMs and gold chlorocomplexes with the cation of onium salt N(1-carbaethoxypentadecyl)-trimethyl ammonium bromide was considered. The calibration curves, limits of detection and matrix effects were evaluated in the presence of 0.003 mol dm(-3) of onium salt (1.3 mg cm(-3)) and 0.1 mol dm(-3) HCl. The values of limits of detection (3 sigma(bl)) of PGMs for all axial ICP instruments were mostly below 10 ng cm(-3). Lateral observation on dual view ICP instrument yielded only 3 times higher detection limits in comparison to the axial mode of the same spectrometer and the detection limits for ICP-MS instrument were on the levels of units or tens of pg cm(-3). These limits of detection did not significantly differ from values obtained with pure solutions. Matrix effects in the presence of onium salt did not exceed 12% depression in the analytical signals. Besides the coefficients of correlation, the uncertainties on centroids of concentrations were calculated for calibration graphs obtained by linear regression. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:859 / 866
页数:8
相关论文
共 29 条
[1]   PLATINUM TRACES IN AIRBORNE PARTICULATE MATTER - DETERMINATION OF WHOLE CONTENT, PARTICLE-SIZE DISTRIBUTION AND SOLUBLE PLATINUM [J].
ALT, F ;
BAMBAUER, A ;
HOPPSTOCK, K ;
MERGLER, B ;
TOLG, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9) :693-696
[2]  
[Anonymous], 1976, PURE APPL CHEM, V45, P99, DOI DOI 10.1351/PAC197645020099
[3]  
BENCKO V, 1991, ENV HLTH CRITERIA PL, P16
[4]  
BOUMANS PWJ, 1987, INDUCTIVELY COUPLED, P102
[5]   CORRECTIONS FOR SPECTRAL INTERFERENCES IN OPTICAL EMISSION SPECTROMETRY WITH SPECIAL REFERENCE TO RF INDUCTIVELY COUPLED PLASMA [J].
BOUMANS, PWJM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1976, 31 (03) :147-152
[6]  
BOUSKA V, 1980, GEOCHEMIE, P457
[7]   EXTRACTIVE SPECTROPHOTOMETRIC DETERMINATION OF PLATINUM, RHODIUM AND IRIDIUM [J].
BRAJTER, K ;
KOZICKA, U .
TALANTA, 1979, 26 (05) :417-419
[8]   HPLC of platinum metals and gold based on their bromo complexes [J].
Dolezal, J ;
Sommer, L .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1997, 62 (07) :1029-1042
[9]  
GUSTAVSSON AGT, 1987, INDUCTIVELY COUPLED, P415
[10]  
JACKWERTH E, 1979, PURE APPL CHEM, V51, P1195