Routine implant removal after fracture surgery: A potentially reducible consumer of hospital resources in trauma units

被引:130
作者
Bostman, O [1 ]
Pihlajamaki, H [1 ]
机构
[1] UNIV HELSINKI,CENT HOSP,DEPT ORTHOPAED & TRAUMATOL,HELSINKI,FINLAND
关键词
hospital resource consumption; implant removal; internal fracture fixation;
D O I
10.1097/00005373-199611000-00013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Assess the workload caused by elective routine removals of internal fracture fixation devices in a large university orthopedic and trauma unit when no premeditated departmental removal policy existed. Materials and Methods: Data on all operations performed during a 7-year period were retrieved. Routine removals of internal fracture fixation implants were analyzed for demographic data and clinical details, Patients requiring additional procedures to manage the fracture besides simple hardware removal were excluded. Nationwide data were included for comparison. Results: A total of 5,095 routine implant removal operations were performed after uneventful fracture union, The mean age of the patients was 42 years. The five most common fracture types were fractures of the ankle, the proximal femur, the tibial shaft. the femoral shaft, and the thoracolumbar spine, In 63% of the procedures, a medium-size or large implant was removed, The mean operation time was 37 minutes, The removals accounted for 29% of all elective operations and for 15% of all operations at the department. The corresponding nationwide figure was 6.3% of all orthopedic operations, the number of implant removals in the whole country being 90 operations per 100,000 person-years. Conclusions: Without a strict departmental removal policy, a remarkable portion of the resources allocated for elective orthopedic operations was spent on routine hardware are removal procedures. A more rational and selective attitude toward implant removals is desirable, Further research on the disadvantages of retained hardware and the complications of implant removals is required.
引用
收藏
页码:846 / 849
页数:4
相关论文
共 19 条
[1]   DOES CORROSION MATTER [J].
BLACK, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :517-520
[2]  
BOSTMAN O, 1991, J TRAUMA, V31, P1400
[3]  
BOSTMAN O, 1989, J TRAUMA, V29, P639
[4]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[5]   REFRACTURE AFTER REMOVAL OF A CONDYLAR PLATE FROM THE DISTAL 3RD OF THE FEMUR [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (07) :1013-1018
[6]  
BRWN RM, 1993, J R COLL SURG EDINB, V38, P96
[7]  
CHAPMAN MW, 1993, OPERATIVE ORTHOPAEDI, P685
[8]   CORRELATION OF TISSUE REACTION TO CORROSION IN OSTEOSYNTHETIC DEVICES [J].
FRENCH, HG ;
COOK, SD ;
HADDAD, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (07) :817-828
[9]   REFRACTURE OF BONES OF THE FOREARM AFTER PLATE REMOVAL [J].
HIDAKA, S ;
GUSTILO, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1241-1243
[10]   DEEP, LATE INFECTIONS ASSOCIATED WITH INTERNAL-FIXATION IN CHILDREN [J].
HIGHLAND, TR ;
LAMONT, RL .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1985, 5 (01) :59-64