Retention behaviours and separation of carboxylic acids by ion-exchange chromatography

被引:25
作者
Hajós, P
Nagy, L
机构
[1] Univ Veszprem, Dept Analyt Chem, H-8201 Veszprem, Hungary
[2] Hungarian Acad Sci, Res Grp Analyt Chem, H-8201 Veszprem, Hungary
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 717卷 / 1-2期
关键词
reviews; carboxylic acids;
D O I
10.1016/S0378-4347(98)00247-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of high-performance suppressed ion chromatography for the separation of aliphatic carboxylic acids has become an attractive and viable method during the past years. This paper summarises and critically concludes that some new results have been achieved in separation and detection of low-molecular-mass organic anions. Theoretical and practical considerations of ion-exchange selectivity to control retention behaviour are presented. The major factors that determine the separation ability of ion-exchange chromatography (pK(a) values, the aliphatic nature and valency of solutes, eluent pH and the chemical composition of stationary phases) are discussed. The question of isocratic vs. gradient elution and different separation modes are examined briefly. The potentials and limitations of the developed methods and their specific application areas are outlined, (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 38
页数:12
相关论文
共 38 条
[1]   DIETARY CARCINOGENS AND ANTICARCINOGENS - OXYGEN RADICALS AND DEGENERATIVE DISEASES [J].
AMES, BN .
SCIENCE, 1983, 221 (4617) :1256-1264
[2]   SIMULTANEOUS DETERMINATION OF SMALL ORGANIC AND INORGANIC ANIONS IN ENVIRONMENTAL WATER SAMPLES BY ION-EXCHANGE CHROMATOGRAPHY [J].
AMMANN, AA ;
RUTTIMANN, TB .
JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) :259-269
[3]   2-DIMENSIONAL CONDUCTOMETRIC DETECTION IN ION CHROMATOGRAPHY - SEQUENTIAL SUPPRESSED AND SINGLE COLUMN DETECTION [J].
BERGLUND, I ;
DASGUPTA, PK ;
LOPEZ, JL ;
NARA, O .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1192-1198
[4]   Ion chromatographic separation of carboxylic acids - Prediction of retention data [J].
Bruzzoniti, MC ;
Mentasti, E ;
Sarzanini, C ;
Hajos, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 770 (1-2) :13-22
[5]  
CALLUL M, 1992, J CHROMATOGR, V590, P215
[6]  
*DION, 1997, DION PROD SEL GUID
[7]  
DORFNER K, 1991, ION EXCHANGES, P317
[8]  
DUNN MH, 1989, LC GC-MAG SEP SCI, V7, P138
[9]  
FISHER K, 1994, CHROMATOGRAPHIA, V38, P43
[10]   COMPUTER-ASSISTED OPTIMIZATION OF ELUENT CONCENTRATION AND PH IN ION CHROMATOGRAPHY [J].
HADDAD, PR ;
COWIE, CE .
JOURNAL OF CHROMATOGRAPHY, 1984, 303 (02) :321-330