Electrospray ionization from a droplet deposited on a surface-modified glass rod

被引:47
作者
Jeng, JY [1 ]
Shiea, J [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
关键词
SPRAY MASS-SPECTROMETRY; GENERATING ELECTROSPRAY; REDUCTION; INTERFACE; WIRE;
D O I
10.1002/rcm.1109
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports development of a non-mechanical electrospray ionization (ESI) method to generate electrospray from a droplet deposited on an optical fiber coated with a thin gold or Nafion film. Modification of the surface of the optical fiber in this manner increases its wettability, such that a droplet of the aqueous sample solution can adhere sufficiently strongly to the tip of the fiber. The aqueous sample solution was deposited near the tip of the fiber with a micropipette. When a high voltage (2000 V) was applied to the fiber by electrical connection through the gold film, the sample solution moved and hung at the tip of the fiber. Simultaneously, ESI was generated from the sample droplet. Multiply charged peptide and protein ions were detected by connecting the ESI source to a quadrupole mass analyzer. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:1709 / 1713
页数:5
相关论文
共 19 条
[1]   THE COMING OF AGE OF MASS-SPECTROMETRY IN PEPTIDE AND PROTEIN CHEMISTRY [J].
BIEMANN, K .
PROTEIN SCIENCE, 1995, 4 (09) :1920-1927
[2]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[3]   CHARGE-STATE REDUCTION OF OLIGONUCLEOTIDE NEGATIVE-IONS FROM ELECTROSPRAY-IONIZATION [J].
CHENG, XH ;
GALE, DC ;
UDSETH, HR ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :586-593
[4]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[5]   DROPLET ELECTROSPRAY MASS-SPECTROMETRY [J].
HAGER, DB ;
DOVICHI, NJ ;
KLASSEN, J ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :3944-3949
[6]   QUANTITATIVE CAPILLARY ELECTROPHORESIS ION SPRAY MASS-SPECTROMETRY ON A BENCHTOP ION-TRAP FOR THE DETERMINATION OF ISOQUINOLINE ALKALOIDS [J].
HENION, JD ;
NLORDEHAI, AV ;
CAI, JY .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2103-2109
[7]   SONIC SPRAY MASS-SPECTROMETRY [J].
HIRABAYASHI, A ;
SAKAIRI, M ;
KOIZUMI, H .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2878-2882
[8]  
Hong CM, 1999, RAPID COMMUN MASS SP, V13, P21, DOI 10.1002/(SICI)1097-0231(19990115)13:1<21::AID-RCM441>3.0.CO
[9]  
2-7
[10]  
Kebarle P., 1997, ELECTROSPRAY IONIZAT