Evaluation of a low sample consumption, high-efficiency nebulizer for elemental analysis of biological samples using inductively coupled plasma mass spectrometry

被引:48
作者
Liu, HY
Montaser, A
Dolan, SP
Schwartz, RS
机构
[1] GEORGE WASHINGTON UNIV,DEPT CHEM,WASHINGTON,DC 20052
[2] US FDA,ELEMENTAL RES BRANCH,WASHINGTON,DC 20204
[3] US CUSTOMS SERV,WASHINGTON,DC 20229
关键词
nebulizer; elemental analysis; biological samples; inductively coupled plasma mass spectrometry;
D O I
10.1039/ja9961100307
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The applications of a pneumatically driven high-efficiency nebulizer (HEN), operated at a solution uptake rate of 85 mu l min(-1), are reported for the analysis of digested biological standard reference materials using argon ICP-MS. Laser Fraunhofer diffraction also is used to acquire droplet-size distributions for the tertiary aerosol from the HEN. Three Standard Reference Materials (SRM 1566 Oyster Tissue, 1577a Bovine Liver and 1571 Orchard Leaves, National Institute of Standards and Technology) are microwave/nitric acid digested and analysed by external calibration with four internal standards. Results for the measurement of 10 elements in the SRMs are presented. In general, good agreement is obtained between the measured and certified values. The droplet-size distributions of the tertiary aerosol of biological materials tested are nearly identical to that of the digestion blank solution consisting of 10% HNO3.
引用
收藏
页码:307 / 311
页数:5
相关论文
共 40 条
  • [1] DETERMINATION OF IODINE AND BROMINE IN PLASMA AND URINE BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    ALLAIN, P
    MAURAS, Y
    DOUGE, C
    JAUNAULT, L
    DELAPORTE, T
    BEAUGRAND, C
    [J]. ANALYST, 1990, 115 (06) : 813 - 815
  • [2] APEL CT, 1989, ICP INFORM NEWSL, V14, P503
  • [3] RAPID AND SENSITIVE DETERMINATION OF IODINE IN FRESH MILK AND MILK POWDER BY INDUCTIVELY COUPLED PLASMA - MASS-SPECTROMETRY (ICP-MS)
    BAUMANN, H
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (07): : 809 - 812
  • [4] USE OF EXTERNAL CALIBRATION FOR THE DETERMINATION OF TRACE-METALS IN BIOLOGICAL-MATERIALS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    BEAUCHEMIN, D
    MCLAREN, JW
    BERMAN, SS
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) : 775 - 780
  • [5] THIMBLE GLASS FRIT NEBULIZER FOR ATOMIC SPECTROMETRY
    CLIFFORD, RH
    MONTASER, A
    SINEX, SA
    CAPAR, SG
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (24) : 2777 - 2784
  • [6] ANALYSIS OF BIOLOGICAL REFERENCE MATERIALS, PREPARED BY MICROWAVE DISSOLUTION, USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    FRIEL, JK
    SKINNER, CS
    JACKSON, SE
    LONGERICH, HP
    [J]. ANALYST, 1990, 115 (03) : 269 - 273
  • [7] Greenfield S., 1992, INDUCTIVELY COUPLED
  • [8] Gustavsson A.G.T., 1992, INDUCTIVELY COUPLED, V2nd
  • [9] HORLICK G, 1992, INDUCTIVELY COUPLED
  • [10] Jarvis K. E., 1992, HDB INDUCTIVELY COUP, DOI [DOI 10.1007/BF02290251, 10.1007/BF02290251]