Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study

被引:24
作者
Burkhart, Klaus J. [1 ]
Nowak, Tobias E. [1 ]
Gradl, Georg [2 ]
Klitscher, Daniela [1 ]
Mehling, Isabella [1 ]
Mehler, Dorothea [1 ]
Mueller, Lars P. [1 ]
Rommens, Pol M. [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Ctr Musculoskeletal Surg, Dept Trauma Surg, D-55131 Mainz, Germany
[2] Univ Rostock, Dept Trauma Surg, D-18057 Rostock, Germany
关键词
Distal radius; Stability; Intramedullary nailing; Locking plate; PROSPECTIVE RANDOMIZED-TRIAL; INTERNAL-FIXATION; INTERFRAGMENTARY MOVEMENTS; INTRAARTICULAR FRACTURES; EXTERNAL FIXATION; CADAVERIC MODEL; OPEN REDUCTION; VOLAR; COMPLICATIONS; DISTRACTION;
D O I
10.1016/j.clinbiomech.2010.06.004
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: The purpose of this study was to compare the stability of a 2.4 mm palmar locking compression plate and a new intramedullary nail-plate-hybrid Targon DR for dorsally comminuted distal radius fractures. Methods: An extraarticular 10 mm dorsally open wedge osteotomy was created in 8 pairs of fresh frozen human radii to simulate an AO-A3-fracture. The fractures were stabilized using one of the fixation methods. The specimens were loaded axially with 200 N and dorsal-excentrically with 80 N. 2000 cycles of dynamic loading and axial loading-to-failure were performed. Findings: Axial loading revealed that intramedullary osteosynthesis (Targon DR: 369 N/mm) was significantly (p=0.017) stiffer than plate osteosynthesis (Locking compression plate: 131 N/mm). With 214 N/mm the intramedullary nail also showed higher stability during dorsal excentric loading than the Locking compression plate with 51 N/mm (p=0.012). After 2000 cycles of axial loading with 80 N the Targon DR-group was significantly stiffer than the Locking compression plate-group under both loading patterns. Neither group showed significant changes in stiffness after 2000 cycles. Under dorsal excentric loading the Targon DR-group was still significantly stiffer with 212 N/mm than the Locking compression plate-group with 45 N/mm (p=0.012). The load to failure tests demonstrated higher stability of intramedullary nailing (625 N) when compared to plate osteosynthesis (403 N) (p<0.025). Interpretation: The study shows that intramedullary fixation of a distal AO-A3 radial fracture is biomechanically more stable than volar fixed-angle plating under axial and dorsal-excentric loading in an experimental setup. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:771 / 775
页数:5
相关论文
共 35 条
[1]
FORCES IN THE NORMAL AND ABNORMAL HAND [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (02) :202-211
[2]
Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]
Internal fixation of distal radius fractures with novel intramedullary implants [J].
Brooks, Kenneth R. ;
Capo, John T. ;
Warburton, Mark ;
Tan, Virak .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (445) :42-50
[4]
3-DIMENSIONAL FORCE ANALYSIS OF FINGER JOINTS IN SELECTED ISOMETRIC HAND FUNCTIONS [J].
CHAO, EY ;
OPGRANDE, JD ;
AXMEAR, FE .
JOURNAL OF BIOMECHANICS, 1976, 9 (06) :387-396
[5]
Management of distal radial fractures [J].
Chen, Neal C. ;
Jupiter, Jesse B. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :2051-2062
[6]
Influence of size and stability of the osteotomy gap on the success of fracture healing [J].
Claes, L ;
Augat, P ;
Suger, G ;
Wilke, HJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (04) :577-584
[7]
Mechanical factors influencing callus healing [J].
Claes, L ;
Wolf, S ;
Augat, P .
CHIRURG, 2000, 71 (09) :989-994
[8]
Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction - A biomechanic study in a cadaveric model [J].
Drobetz, H ;
Bryant, AL ;
Pokorny, T ;
Spitaler, R ;
Leixnering, M ;
Jupiter, JB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (04) :615-622
[9]
Interfragmentary movements in the early phase of healing in distraction and correction osteotomies stabilize with ring fixators [J].
Duda, GN ;
Sporrer, S ;
Sollmann, M ;
Hoffmann, JE ;
Kassi, JP ;
Khodadadyan, C ;
Raschke, M .
LANGENBECKS ARCHIVES OF SURGERY, 2003, 387 (11-12) :433-440
[10]
Dunning CE, 1999, J HAND SURG-AM, V24A, P992