Feasibility studies of simultaneous multianalyte amperometric immunoassay based on spatial resolution

被引:15
作者
Ding, Y [1 ]
Zhou, LP [1 ]
Halsall, HB [1 ]
Heineman, WR [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
关键词
analyte-specific antibodies; amperometric detection; multianalyte immunoassay; spatial resolution;
D O I
10.1016/S0731-7085(98)00186-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multianalyte immunoassay concept based on the geometric separation of different analyte-specific antibodies has been demonstrated. The assay and amperometric detection are done in a cell with two working electrodes controlled at the same potential, and the amperometric signal at each electrode is monitored. The distance between any two adjacent electrodes in this prototype is 2.5 mm, and during the course of amperometric measurement, the product formed at one electrode does not reach the other working electrode within 20 min after the addition of enzyme substrate, Thus, the method relies on the spatial resolution between the different antibodies being such that measurements are taken before cross-interference due to diffusion can occur. Identical enzyme labels (alkaline phosphatase, ALP) and substrates (p-aminophenyl phosphate, PAPP) are used for all analytes. Alkaline phosphatase-conjugated rat anti-mouse IgG was immobilized by passive adsorption. Our studies showed that this concept is feasible and can be applied to the simultaneous measurement of multiple analytes. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:153 / 161
页数:9
相关论文
共 30 条
[1]  
BARD AJ, 1980, ELECTROCHEMICAL METH, P128
[2]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[3]  
EKINS R, 1993, CLIN CHEM, V39, P369
[4]  
EKINS RP, 1991, CLIN CHEM, V37, P1955
[5]  
GIL EP, 1990, CLIN CHEM, V36, P662
[6]  
GUTCHO S, 1977, CLIN CHEM, V23, P1609
[7]   SIMULTANEOUS IMMUNOASSAY USING ELECTROCHEMICAL DETECTION OF METAL-ION LABELS [J].
HAYES, FJ ;
HALSALL, HB ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1860-1865
[8]   SIMULTANEOUS RADIOIMMUNOASSAY OF THYROID-HORMONES IN UNEXTRACTED SERUM [J].
HAYNES, SP ;
GOLDIE, DJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1977, 14 (JAN) :12-15
[9]   STRATEGIES FOR ELECTROCHEMICAL IMMUNOASSAY [J].
HEINEMAN, WR ;
HALSALL, HB .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :1321-&
[10]  
HEMMILA I, 1987, CLIN CHEM, V33, P2281