Predicted loading on the menisci during gait: The effect of horn laxity

被引:34
作者
Guess, Trent M. [1 ]
Razu, Swithin [1 ]
Jahandar, Hamidreza [1 ]
Stylianou, Antonis [2 ]
机构
[1] Univ Missouri, Dept Phys Therapy, Dept Orthopaed Surg, Columbia, MO 65211 USA
[2] Univ Missouri, Kansas City, MO 64110 USA
关键词
Menisci; Meniscal extrusion; Musculoskeletal model; Gait; Knee; Computational biomechanics; MEDIAL COLLATERAL LIGAMENT; FINITE-ELEMENT MODEL; POSTERIOR CRUCIATE LIGAMENT; KNEE OSTEOARTHRITIS; RADIOGRAPHIC MEASUREMENT; 3-DIMENSIONAL MODEL; CONTACT MECHANICS; PATELLAR TENDON; BODY POSITION; ANATOMY;
D O I
10.1016/j.jbiomech.2015.01.047
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Radiographic measurements have established a link between meniscus extrusion and meniscus degeneration as well as with knee osteoarthritis. The presented work combines medical imaging with motion capture data from two healthy female subjects to create subject specific knee models that predict tibio-menisco-femoral contact forces and ligament forces during muscle driven simulations of barefoot gait. The developed computational models were used to explore the relationship between the extent of meniscal extrusion and biomechanical function by altering the laxity of the meniscal horn attachments during gait. The extrusion distance increased as laxity increased and the amount of contact force transferred through the menisci during gait decreased rapidly as the meniscal attachments became more lax. Horn attachment lengths that were 20% longer than MRI attachment lengths resulted in an almost complete loss of force transfer through the menisci during the gait cycle. Relatively small changes (2-3 mm) in the lengths at which horn bundles first become taut, manifested in large changes in the capacity of the tissue to transmit forces. As meniscal horn attachment laxity increased from 80% to 120% of the MRI measured horn distance, medial meniscus extrusion increased 3.9 mm for the first subject and 2.7 mm for the second subject. For the same horn laxity changes, the percent of medial tibiofemoral contact force transmitted through the medial meniscus during early stance decreased from 51% to 8% and from 36% to 14% for the two subjects. The results of our study show that increased meniscal extrusion occurs with increased laxity of the meniscal tibia attachments and this increased laxity results in loss of meniscal function. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1490 / 1498
页数:9
相关论文
共 67 条
[1]
Suture-Only Fixation Technique Leads to a Higher Degree of Extrusion Than Bony Fixation in Meniscal Allograft Transplantation [J].
Abat, Ferran ;
Eduardo Gelber, Pablo ;
Ignacio Erquicia, Juan ;
Pelfort, Xavier ;
Gonzalez-Lucena, Gemma ;
Carlos Monllau, Juan .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (07) :1591-1596
[2]
From meniscus to bone: A quantitative evaluation of structure and function of the human meniscal attachments [J].
Abraham, Adam C. ;
Donahue, Tammy L. Haut .
ACTA BIOMATERIALIA, 2013, 9 (05) :6322-6329
[3]
INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .1. TIBIAL SURFACE OF THE KNEE [J].
AHMED, AM ;
BURKE, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :216-225
[4]
The Effects of Meniscus Injury on the Development of Knee Osteoarthritis Data From the Osteoarthritis Initiative [J].
Badlani, Jayshiv T. ;
Borrero, Camilo ;
Golla, Saraswati ;
Harner, Christopher D. ;
Irrgang, James J. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (06) :1238-1244
[5]
Multibody dynamic simulation of knee contact mechanics [J].
Bei, YH ;
Fregly, BJ .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (09) :777-789
[6]
Beillas P, 2004, J BIOMECH, V37, P1019, DOI [10.1016/j.jbiomech.2003.11.022, 10.1016/j jbiomech.2003.11.022]
[7]
Sensitivity of the tibio-femoral response to finite element modeling parameters [J].
LBMC, French National Institute for Transport and Safety Research, INRETS UCBL1 UMR-T, 9406, Bron, France ;
不详 ;
不详 .
Comput. Methods Biomech. Biomed. Eng., 2007, 3 (209-221) :209-221
[8]
Meniscal tear and extrusion are strongly associated with progression of symptomatic knee osteoarthritis as assessed by quantitative magnetic resonance imaging [J].
Berthiaume, MJ ;
Raynauld, JP ;
Martel-Pelletier, J ;
Labonté, F ;
Beaudoin, G ;
Bloch, DA ;
Choquette, D ;
Haraoui, B ;
Altman, RD ;
Hochberg, M ;
Meyer, JM ;
Cline, GA ;
Pelletier, JP .
ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 (04) :556-563
[9]
ARTICULAR CONTACT IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
KUIPER, JH ;
HUISKES, R ;
GROOTENBOER, HJ .
JOURNAL OF BIOMECHANICS, 1991, 24 (11) :1019-1031
[10]
LIGAMENT-BONE INTERACTION IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
HUISKES, R .