Underdrain Configuration to Enhance Bioretention Exfiltration to Reduce Pollutant Loads

被引:137
作者
Brown, R. A. [1 ]
Hunt, W. F. [1 ]
机构
[1] N Carolina State Univ, Dept Biol & Agr Engn, Raleigh, NC 27695 USA
关键词
Internal water storage (IWS) zone; Bioretention; Hydrology; Water quality; Drainage configuration; Coastal plain; Exfiltration; Low impact development; STORM-WATER; FIELD PERFORMANCE; REMOVAL; HYDROLOGY; RETENTION; EVAPOTRANSPIRATION; MITIGATION; RUNOFF;
D O I
10.1061/(ASCE)EE.1943-7870.0000437
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The bioretention drainage configuration of raising the outlet to create an internal water storage (IWS) layer in the media was originally intended to promote denitrifying conditions. The goal was to reduce nitrate and total nitrogen concentrations in nutrient-sensitive watersheds. Two field studies in the Piedmont region of North Carolina, where the in situ soils typically have high clay content, showed this design feature had potential to enhance exfiltration and reduce drainage from bioretention. Two bioretention cells in Rocky Mount, North Carolina, were monitored for two year-long periods to measure the impact of varying IWS zone depths over sandier underlying soils. Nearly 99% of runoff entering the bioretention cell with sand underlying soil (sand cell) was never directly discharged to the storm water network. However, the hydraulic retention time (contact time) of runoff in the media was less than 3 h, and except for total suspended solids (TSS), minimal pollutant removal was achieved. The other bioretention cell had a sandy clay loam underlying soil (SCL cell); the percentage of runoff leaving via exfiltration and evapotranspiration from this cell was 87% during the monitoring period with a 1.03-m IWS zone depth and 75% when the IWS zone depth was 0.73 m. The underlying soil of the SCL cell had a lower hydraulic conductivity, so water would remain in the IWS zone for up to 7 days. The increased hydraulic retention time in the media resulted in lower outflow concentrations. For events monitored with drainage from the SCL cell, efficiency ratios of all the nitrogen species and TSS exceeded 0.5. As an additional metric of performance, the parking lot runoff and treated runoff from both the SCL and sand cells were compared to concentrations consistent with "good" and "fair" benthic macroinvertebrate health in streams. Using this metric, the parking lot runoff only met the "fair" standard for total nitrogen (TN) and total phosphorus (TP), and treated runoff from the SCL cell achieved the "good" standard for both TN and TP. However, because of the short hydraulic retention time of runoff in the media for the sand cell, this cell only maintained the "fair" standard for TN and did not achieve the "fair" standard for TP. DOI: 10.1061/(ASCE)EE.1943-7870.0000437. (C) 2011 American Society of Civil Engineers.
引用
收藏
页码:1082 / 1091
页数:10
相关论文
共 35 条
  • [1] COMPARISON OF METHODS FOR ESTIMATING REF-ET
    AMATYA, DM
    SKAGGS, RW
    GREGORY, JD
    [J]. JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 1995, 121 (06) : 427 - 435
  • [2] [Anonymous], 1995, Standard methods for the examination of water and wastewater, V19th
  • [3] [Anonymous], 1983, 600479020 USEPA
  • [4] [Anonymous], 49 COL STAT U
  • [5] [Anonymous], 2004, NAT ENG HDB 630
  • [6] Field performance of bioretention: Hydrology impacts
    Davis, Allen P.
    [J]. JOURNAL OF HYDROLOGIC ENGINEERING, 2008, 13 (02) : 90 - 95
  • [7] Field performance of bioretention: Water quality
    Davis, Allen P.
    [J]. ENVIRONMENTAL ENGINEERING SCIENCE, 2007, 24 (08) : 1048 - 1064
  • [8] Bioretention Technology: Overview of Current Practice and Future Needs
    Davis, Allen P.
    Hunt, William F.
    Traver, Robert G.
    Clar, Michael
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2009, 135 (03) : 109 - 117
  • [9] Laboratory study of biological retention for urban stormwater management
    Davis, AP
    Shokouhian, M
    Sharma, H
    Minami, C
    [J]. WATER ENVIRONMENT RESEARCH, 2001, 73 (01) : 5 - 14
  • [10] Saturation to improve pollutant retention in a rain garden
    Dietz, ME
    Clausen, JC
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (04) : 1335 - 1340