Detection of suspected brain infarctions on CT can be significantly improved with temporal subtraction images

被引:16
作者
Akasaka, Thai [1 ]
Yakami, Masahiro [1 ,2 ]
Nishio, Mizuho [1 ,2 ]
Onoue, Koji [1 ]
Aoyama, Gakuto [3 ]
Nakagomi, Keita [3 ]
Iizuka, Yoshio [3 ]
Kubo, Takeshi [1 ]
Emoto, Yutaka [4 ]
Satoh, Kiyohide [3 ]
Yamamoto, Hiroyuki [5 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Diagnost Imaging & Nucl Med, Sakyo Ku, 54 Kawahara Cho, Kyoto, Kyoto 6068507, Japan
[2] Kyoto Univ Hosp, Preempt Med & Lifestyle Related Dis Res Ctr, Sakyo Ku, 53 Kawahara Cho, Kyoto, Kyoto 6068507, Japan
[3] Canon Inc, Med Imaging Syst Dev Ctr, R&D Headquarters, Ohta Ku, 30-2,Shimomaruko 3 Chome, Tokyo 1468501, Japan
[4] Kyoto Coll Med Sci, 1-3 Imakita,Koyamahigashi Cho,Sonobe Cho, Kyoto 6220041, Japan
[5] Canon Inc, Corp Planning Headquarters, Business Dev Promot Ctr, Ohta Ku, 30-2,Shimomaruko 3 Chome, Tokyo 1468501, Japan
关键词
Multidetector computed tomography; Stroke; Brain infarction; Computer assisted diagnosis; Subtraction technique; DIGITAL CHEST RADIOGRAPHS; LUNG NODULE DETECTION; CEREBRAL INFARCTION; ROC ANALYSIS; DIAGNOSIS; STROKE; SIGN;
D O I
10.1007/s00330-018-5655-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
ObjectiveTo assess whether temporal subtraction (TS) images of brain CT improve the detection of suspected brain infarctions.MethodsStudy protocols were approved by our institutional review board, and informed consent was waived because of the retrospective nature of this study. Forty-two sets of brain CT images of 41 patients, each consisting of a pair of brain CT images scanned at two time points (previous and current) between January 2011 and November 2016, were collected for an observer performance study. The 42 sets consisted of 23 cases with a total of 77 newly developed brain infarcts or hyperdense artery signs confirmed by two radiologists who referred to additional clinical information and 19 negative control cases. To create TS images, the previous images were registered to the current images by partly using a non-rigid registration algorithm and then subtracted. Fourteen radiologists independently interpreted the images to identify the lesions with and without TS images with an interval of over 4 weeks. A figure of merit (FOM) was calculated along with the jackknife alternative free-response receiver-operating characteristic analysis. Sensitivity, number of false positives per case (FPC) and reading time were analyzed by the Wilcoxon signed-rank test.ResultsThe mean FOM increased from 0.528 to 0.737 with TS images (p < 0.0001). The mean sensitivity and FPC improved from 26.5% and 0.243 to 56.0% and 0.153 (p < 0.0001 and p = 0.239), respectively. The mean reading time was 173 s without TS and 170 s with TS (p = 0.925).ConclusionThe detectability of suspected brain infarctions was significantly improved with TS CT images.Key Points center dot Although it is established that MRI is superior to CT in the detection of strokes, the first choice of modality for suspected stroke patients is often CT.center dot An observer performance study with 14 radiologists was performed to evaluate whether temporal subtraction images derived from a non-rigid transformation algorithm can significantly improve the detectability of newly developed brain infarcts on CT.center dot Temporal subtraction images were shown to significantly improve the detectability of newly developed brain infarcts on CT.
引用
收藏
页码:759 / 769
页数:11
相关论文
共 21 条
[1]
Sequence-specific MR Imaging Findings That Are Useful in Dating Ischemic Stroke [J].
Allen, Laura M. ;
Hasso, Anton N. ;
Handwerker, Jason ;
Farid, Hamed .
RADIOGRAPHICS, 2012, 32 (05) :1285-1297
[2]
Temporal Subtraction Method for Lung Nodule Detection on Successive Thoracic CT Soft-Copy Images1 [J].
Aoki, Takatoshi ;
Murakami, Seiichi ;
Kim, Hyoungseop ;
Fujii, Masami ;
Takahashi, Hiroyuki ;
Oki, Hodaka ;
Hayashida, Yoshiko ;
Katsuragawa, Shigehiko ;
Shiraishi, Junji ;
Korogi, Yukunori .
RADIOLOGY, 2014, 271 (01) :255-261
[3]
Usefulness of Computerized Method for Lung Nodule Detection in Digital Chest Radiographs Using Temporal Subtraction Images [J].
Aoki, Takatoshi ;
Oda, Nobuhiro ;
Yamashita, Yoshiko ;
Yamamoto, Keiji ;
Korogi, Yukunori .
ACADEMIC RADIOLOGY, 2011, 18 (08) :1000-1005
[4]
Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[5]
Computing large deformation metric mappings via geodesic flows of diffeomorphisms [J].
Beg, MF ;
Miller, MI ;
Trouvé, A ;
Younes, L .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2005, 61 (02) :139-157
[6]
Birenbaum D, 2011, WEST J EMERG MED, V12, P67
[7]
A Brief History of Free-Response Receiver Operating Characteristic Paradigm Data Analysis [J].
Chakraborty, Dev P. .
ACADEMIC RADIOLOGY, 2013, 20 (07) :915-919
[8]
Magnetic resonance imaging and computed tomography in emergency assessment of patients with suspected acute stroke: a prospective comparison [J].
Chalela, Julio A. ;
Kidwell, Chelsea S. ;
Nentwich, Lauren M. ;
Luby, Marie ;
Butman, John A. ;
Demchuk, Andrew M. ;
Hill, Michael D. ;
Patronas, Nicholas ;
Latour, Lawrence ;
Warach, Steven .
LANCET, 2007, 369 (9558) :293-298
[9]
Non-rigid image registration: theory and practice [J].
Crum, WR ;
Hartkens, T ;
Hill, DLG .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 :S140-S153
[10]
CT and diffusion-weighted MR imaging in randomized order - Diffusion-weighted imaging results in higher accuracy and lower interrater variability in the diagnosis of hyperacute ischemic stroke [J].
Fiebach, JB ;
Schellinger, PD ;
Jansen, O ;
Meyer, M ;
Wilde, P ;
Bender, J ;
Schramm, P ;
Juttler, E ;
Oehler, J ;
Hartmann, M ;
Hahnel, S ;
Knauth, M ;
Hacke, W ;
Sartor, K .
STROKE, 2002, 33 (09) :2206-2210