Influence of myopia and aging on the optimal spherical aberration of soft contact lenses

被引:17
作者
Chateau, N [1 ]
Blanchard, A
Baude, D
机构
[1] Essilor Opt Contact, F-94000 Creteil, France
[2] Univ Paris Sud, F-91405 Orsay, France
来源
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION | 1998年 / 15卷 / 09期
关键词
D O I
10.1364/JOSAA.15.002589
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Soft contact lenses with different levels of third-order spherical aberration were tested in two samples of subjects aged between 20 and 45 years: 18 emmetropes and 19 myopes. Contrast sensitivity was measured at 12 cycles/degree to determine the optimal lens spherical aberration required by each individual. The optimal third-order coefficient was found to be negative on average in both refractive error groups. Myopic subjects required contact lenses with more negative spherical aberration than did emmetropes. The optimal aberration was also found to become increasingly negative with aging. The rate of this age-related change was faster in the myopic group. In comparison with aberration-free soft contact lenses, an improvement in contrast detection threshold of more than 25% was observed with optimal spherical aberration in half of the myopic subjects. (C) 1998 Optical Society of America.
引用
收藏
页码:2589 / 2596
页数:8
相关论文
共 39 条
[1]   DOUBLE-PASS MEASUREMENTS OF THE RETINAL-IMAGE QUALITY WITH UNEQUAL ENTRANCE AND EXIT PUPIL SIZES AND THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM [J].
ARTAL, P ;
IGLESIAS, I ;
LOPEZGIL, N ;
GREEN, DG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (10) :2358-2366
[2]   ABERRATIONS ASSOCIATED WITH RIGID CONTACT-LENSES [J].
ATCHISON, DA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (10) :2267-2273
[3]   ACCOMMODATION AND PRESBYOPIA [J].
ATCHISON, DA .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1995, 15 (04) :255-272
[4]   MEASUREMENT OF MONOCHROMATIC OCULAR ABERRATIONS OF HUMAN EYES AS A FUNCTION OF ACCOMMODATION BY THE HOWLAND ABERROSCOPE TECHNIQUE [J].
ATCHISON, DA ;
COLLINS, MJ ;
WILDSOET, CF ;
CHRISTENSEN, J ;
WATERWORTH, MD .
VISION RESEARCH, 1995, 35 (03) :313-323
[5]  
BAUDE D, 1990, THESIS U PARIS SUD O
[6]   MEASUREMENT OF THE LONGITUDINAL SPHERICAL-ABERRATION OF SOFT CONTACT-LENSES [J].
BAUER, GT ;
LECHNER, HB .
OPTICS LETTERS, 1979, 4 (07) :224-226
[7]   LONGITUDINAL SPHERICAL-ABERRATION OF MODERN OPHTHALMIC LENSES AND ITS EFFECT ON VISUAL-ACUITY [J].
BAUER, GT .
APPLIED OPTICS, 1980, 19 (13) :2226-2234
[8]  
CAMPBELL CE, 1981, AM J OPTOM PHYS OPT, V58, P212
[9]  
CAMPBELL MCW, 1993, 1993 OSA TECHNICAL D, V3, P12
[10]  
Charman W N, 1976, Br J Physiol Opt, V31, P119