Transthoracic three-dimensional echocardiographic reconstruction of left and right ventricles: In vitro validation and comparison with magnetic resonance imaging

被引:67
作者
Pini, R
Giannazzo, G
DiBari, M
Innocenti, F
Rega, L
Casolo, G
Devereux, RB
机构
[1] UNIV FLORENCE, INST GERONTOL & GERIATR, FLORENCE, ITALY
[2] AZIENDA OSPEDALIERA CAREGGI, DEPT RADIOL, FLORENCE, ITALY
[3] NEW YORK HOSP, CORNELL MED CTR, DEPT MED, NEW YORK, NY 10021 USA
关键词
D O I
10.1016/S0002-8703(97)70212-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two-dimensional (2D) echocardiographic and angiographic measurements of ventricular volumes are limited by geometric assumptions concerning cavity shape. We compared in vitro the accuracy of a three-dimensional (3D) echocardiographic system suitable for transthoracic imaging to magnetic resonance imaging (MRI) in the measurement of left and right ventricular volumes. Ventricular cast volumes from 14 excised formalin-fixed sheep hearts filled with an agarose solution were compared with data derived from 3D echocardiography and MRI. Left and right ventricular volumes from 3D echocardiographic reconstructions agreed well with actual volumes without significant underestimation or overestimation. MRI progressively underestimated left ventricular volumes as these increased and systematically underestimated right ventricular volumes. Our echocardiographic system designed for 3D transthoracic imaging combines excellent measurements of left and right ventricular volumes and the computed reconstruction of tomographic slices with the full spatial resolution of the original 2D images. Thus in this in vitro model, 3D echocardiography exhibited greater accuracy than MRI.
引用
收藏
页码:221 / 229
页数:9
相关论文
共 31 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   DETERMINATION OF RIGHT ATRIAL AND RIGHT VENTRICULAR SIZE BY 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
BOMMER, W ;
WEINERT, L ;
NEUMANN, A ;
NEEF, J ;
MASON, DT ;
DEMARIA, A .
CIRCULATION, 1979, 60 (01) :91-100
[3]   INITIAL EXPERIENCE WITH A MULTIPLANE TRANSESOPHAGEAL ECHO-TRANSDUCER - ASSESSMENT OF DIAGNOSTIC POTENTIAL [J].
FLACHSKAMPF, FA ;
HOFFMANN, R ;
VERLANDE, M ;
SCHNEIDER, W ;
AMELING, W ;
HANRATH, P .
EUROPEAN HEART JOURNAL, 1992, 13 (09) :1201-1206
[4]   A MECHANICAL ARM FOR SPATIAL REGISTRATION OF TWO-DIMENSIONAL ECHOCARDIOGRAPHIC SECTIONS [J].
GEISER, EA ;
CHRISTIE, LG ;
CONETTA, DA ;
CONTI, CR ;
GOSSMAN, GS .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (01) :89-101
[5]   A NEW INTEGRATED SYSTEM FOR 3-DIMENSIONAL ECHOCARDIOGRAPHIC RECONSTRUCTION - DEVELOPMENT AND VALIDATION FOR VENTRICULAR VOLUME WITH APPLICATION IN HUMAN-SUBJECTS [J].
HANDSCHUMACHER, MD ;
LETHOR, JP ;
SIU, SC ;
MELE, D ;
RIVERA, JM ;
PICARD, MH ;
WEYMAN, AE ;
LEVINE, RA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (03) :743-753
[6]  
HANDSCHUMACHER MD, 1994, CIRCULATION, V90, P338
[7]  
Jiang L, 1994, J Am Soc Echocardiogr, V7, P150
[8]   VISUALLY DETERMINED LONG-AXIS AND SHORT-AXIS PARASTERNAL VIEWS AND 4-CHAMBER AND 2-CHAMBER APICAL ECHOCARDIOGRAPHIC VIEWS DO NOT CONSISTENTLY REPRESENT PAIRED ORTHOGONAL PROJECTIONS [J].
KATZ, AS ;
WALLERSON, DC ;
PINI, R ;
DEVEREUX, RB .
AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1993, 7 (02) :65-70
[9]   ECHOCARDIOGRAPHIC MEASUREMENT OF RIGHT VENTRICULAR VOLUME [J].
LEVINE, RA ;
GIBSON, TC ;
ARETZ, T ;
GILLAM, LD ;
GUYER, DE ;
KING, ME ;
WEYMAN, AE .
CIRCULATION, 1984, 69 (03) :497-505
[10]  
LONGMORE DB, 1985, LANCET, V1, P1360