Cathodic protection criteria of thermally insulated pipeline buried in soil

被引:114
作者
Kim, JG [1 ]
Kim, YW [1 ]
机构
[1] Sungkyunkwan Univ, Dept Met Engn, Jangan Gu, Suwon 440746, South Korea
关键词
cathodic protection; thermally insulated pipeline; polyurethane foam; polarization; Tafel line; cathodic protection potential; synthetic ground water;
D O I
10.1016/S0010-938X(01)00015-4
中图分类号
T [工业技术];
学科分类号
08 [工学];
摘要
The effect of temperature on the cathodic protection criteria of a pipeline steel under insulation was studied in the temperature range 25-95 degreesC in synthetic ground water. Sufficient protection could not be obtained at -0.85 V-CSE at elevated temperatures, while more negative potential than -0.85 V-CSE was required to obtain satisfactory protection. The anodic Tafel lines were used to determine the protection potential at each temperature. The protection potential was shifted to the more negative value as the temperature increased. The most negative potential was measured at 80 degreesC, which decreased to -1.346 V-SCE. Acceptable corrosion rates were achieved when the potential was held at -1.346 V-SCE over the temperature range studied. (C) 2001 Published by Elsevier Science Ltd.
引用
收藏
页码:2011 / 2021
页数:11
相关论文
共 26 条
[1]
[Anonymous], D512 ASTM
[2]
[Anonymous], 1952, CORROSION-US
[3]
[Anonymous], D2216 ASTM
[4]
[Anonymous], 1993, CATHODIC PROTECTION
[5]
ASTM, ASTM G51
[6]
ASTM, ASTM G57 (latest version)
[7]
*ASTM, G1 ASTM
[8]
BARLO TJ, 1984, MATER PERFORMANCE, V23, P9
[9]
BLOUNT FE, 1972, P U OKL CORR CONTR C
[10]
BUCHANAN RA, 1988, SURFACE MODIFICATION, P87