Observing a single hydrogen-like ion in a Penning trap at T=4K

被引:26
作者
Diederich, M [1 ]
Haffner, H
Hermanspahn, N
Immel, M
Kluge, HJ
Ley, R
Mann, R
Quint, W
Stahl, S
Werth, G
机构
[1] Univ Mainz, D-55099 Mainz, Germany
[2] GSI Darmstadt, D-64291 Darmstadt, Germany
来源
HYPERFINE INTERACTIONS | 1998年 / 115卷 / 1-4期
关键词
Penning trap; highly charged ions;
D O I
10.1023/A:1012665109427
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
We describe how a single hydrogen-like ion (C5+) is prepared, cooled with the method of resistive cooling and non-destructively detected with the image-current technique in a cryogenic Penning trap at T = 4 K. The storage time for C5+-ions in the cryogenically pumped vacuum chamber is longer than six months. The experimental techniques of preparing, cooling and detecting highly-charged ions in a Penning trap are relevant for precision experiments such as g-factor measurements, mass spectroscopy and laser spectroscopy.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 21 条
[2]   EXPERIMENTS WITH AN ISOLATED SUBATOMIC PARTICLE AT REST [J].
DEHMELT, H .
REVIEWS OF MODERN PHYSICS, 1990, 62 (03) :525-530
[3]   NONCLASSICAL RADIATION OF A SINGLE STORED ION [J].
DIEDRICH, F ;
WALTHER, H .
PHYSICAL REVIEW LETTERS, 1987, 58 (03) :203-206
[4]   ACCURATE ATOMIC MASS MEASUREMENTS FROM PENNING TRAP MASS COMPARISONS OF INDIVIDUAL IONS [J].
DIFILIPPO, F ;
NATARAJAN, V ;
BRADLEY, M ;
PALMER, F ;
PRITCHARD, DE .
PHYSICA SCRIPTA, 1995, T59 :144-154
[5]   DETERMINATION OF THE ELECTRONS ATOMIC MASS AND THE PROTON/ELECTRON MASS-RATIO VIA PENNING TRAP MASS-SPECTROSCOPY [J].
FARNHAM, DL ;
VANDYCK, RS ;
SCHWINBERG, PB .
PHYSICAL REVIEW LETTERS, 1995, 75 (20) :3598-3601
[6]   THOUSANDFOLD IMPROVEMENT IN THE MEASURED ANTIPROTON MASS [J].
GABRIELSE, G ;
FEI, X ;
OROZCO, LA ;
TJOELKER, RL ;
HAAS, J ;
KALINOWSKY, H ;
TRAINOR, TA ;
KELLS, W .
PHYSICAL REVIEW LETTERS, 1990, 65 (11) :1317-1320
[7]  
GABRIELSE G, 1989, INT J MASS SPECTROM, V93, P121
[8]   SPECIAL RELATIVITY AND THE SINGLE ANTIPROTON - FORTYFOLD IMPROVED COMPARISON OF (P)OVER-BAR AND P CHARGE-TO-MASS RATIOS [J].
GABRIELSE, G ;
PHILLIPS, D ;
QUINT, W ;
KALINOWSKY, H ;
ROULEAU, G ;
JHE, W .
PHYSICAL REVIEW LETTERS, 1995, 74 (18) :3544-3547
[9]   OPEN-ENDCAP PENNING TRAPS FOR HIGH-PRECISION EXPERIMENTS [J].
GABRIELSE, G ;
HAARSMA, L ;
ROLSTON, SL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 88 (2-3) :319-332
[10]   Measurement of the g(j) factor of hydrogenic ions: A sensitive test of bound state QED [J].
Hermanspahn, K ;
Quint, W ;
Stahl, S ;
Tonges, M ;
Bollen, G ;
Kluge, HJ ;
Ley, R ;
Mann, R ;
Werth, G .
HYPERFINE INTERACTIONS, 1996, 99 (1-3) :91-95