Ancillary techniques to facilitate endovascular repair of aortic aneurysms

被引:60
作者
Yano, OJ [1 ]
Faries, PL [1 ]
Morrissey, N [1 ]
Teodorescu, V [1 ]
Hollier, LH [1 ]
Marin, ML [1 ]
机构
[1] Mt Sinai Med Ctr, Dept Surg, Div Vasc Surg, New York, NY 10029 USA
关键词
D O I
10.1067/mva.2001.116005
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The ability to treat abdominal aortoiliac aneurysms and thoracic aortic aneurysms may be limited by coexisting arterial disease. Device deployment may be impaired by occlusive disease and tortuosity of the arteries used to access the aneurysm or by suitability of the implantation sites. In this study we describe the auxiliary procedures performed to circumvent these obstacles and thereby enable endovascular aneurysm repair. Patients and Methods: Between January 1, 1993, and December 31, 1999, 390 patients treated for aneurysm of the aorta with endovascular devices were entered prospectively in a vascular registry. Fifty (12%) of the 390 patients required adjunctive surgical techniques to (1) create or extend the length of the proximal or distal device implantation site or (2) permit device navigation through diseased iliac arteries. Auxiliary techniques used to extend or enhance implantation sites were elephant trunk graft (n = 2), the construction of renovisceral bypass grafts (n = 1), and subclavian artery transposition (n = 2). Plication of the common iliac artery at its bifurcation was performed in conjunction with femorofemoral bypass graft in nine patients to allow preservation of pelvic circulation by avoiding internal iliac artery sacrifice. Construction of a bypass graft to transpose the internal iliac artery orifice was performed in one patient. The auxiliary techniques used to facilitate device navigation were iliac artery angioplasty or stenting (n = 8), external iliac artery endovascular endarterectomy or straightening (n = 14), endoluminal iliofemoral bypass conduit (n = 5), and the construction of an open iliofemoral bypass conduit (n = 8). Results: Successful deployment of the endovascular devices was achieved in 49 (98%) of 50 patients. Auxiliary techniques were successful in providing access for endovascular device deployment in all 35 patients (100%). Mean followup for techniques to facilitate device navigation is 26 months for endovascular procedures and 42 months for the open bypass graft construction patients; no occlusions were observed at this moment. There were five patients with incisional hematomas that did not necessitate intervention. Fourteen (94%) of 15 patients underwent successful device implantation after the auxiliary maneuvers to enhance implantation site. Mean follow-up for implantation site manipulation is 28 months. One of the subclavian transpositions had a new onset of Horner's syndrome, two of nine patients who had common iliac artery ligated had retroperitoneal hematomas that did not necessitate interventions, and no colon ischemia was seen. The patient who underwent nonanatomic bypass grafting of viscero-renal arteries had a retroperitoneal hematoma that necessitated reexploration. Conclusions: Significant coexisting arterial disease may be encountered in patients with aortic or iliac aneurysms. Identification of coexisting arterial diseases is essential to help tailor the appropriate supplemental surgical procedure to allow the performance of endovascular aneurysm repair in patients who would otherwise require open surgical repair.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 22 条
[1]   Anatomical suitability of abdominal aortic aneurysms for endovascular repair [J].
Armon, MP ;
Yusuf, SW ;
Latief, K ;
Whitaker, SC ;
Gregson, RHS ;
Wenham, PW ;
Hopkinson, BR .
BRITISH JOURNAL OF SURGERY, 1997, 84 (02) :178-180
[2]  
Berguer R, 1996, Semin Vasc Surg, V9, P98
[3]   Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[4]   Endovascular repair of abdominal aortic aneurysm: Getting out of trouble [J].
Chuter, TAM ;
Reilly, LM ;
Kerlan, RK ;
Sawhney, R ;
Canto, CJ ;
Ring, EJ ;
Messina, LM .
CARDIOVASCULAR SURGERY, 1998, 6 (03) :232-239
[5]  
Chuter TAM, 1997, J ENDOVASC SURG, V4, P307, DOI 10.1583/1074-6218(1997)004<0307:SROTIA>2.0.CO
[6]  
2
[7]   ENDOVASCULAR STENT-GRAFTING AFTER ARCH ANEURYSM REPAIR USING THE ELEPHANT TRUNK [J].
FANN, JI ;
DAKE, MD ;
SEMBA, CP ;
LIDDELL, RP ;
PFEFFER, TA ;
MILLER, DC .
ANNALS OF THORACIC SURGERY, 1995, 60 (04) :1102-1105
[8]   Special iliac artery considerations during aneurysm endografting [J].
Henretta, JP ;
Karch, LA ;
Hodgson, KJ ;
Mattos, MA ;
Ramsey, DE ;
McLafferty, R ;
Sumner, DS .
AMERICAN JOURNAL OF SURGERY, 1999, 178 (03) :212-218
[9]   TRANSFEMORAL ENDOVASCULAR STENTED GRAFT TREATMENT OF AORTOILIAC AND FEMOROPOPLITEAL OCCLUSIVE DISEASE FOR LIMB SALVAGE [J].
MARIN, ML ;
VEITH, FJ ;
CYNAMON, J ;
SANCHEZ, LA ;
WENGERTER, KR ;
SCHWARTZ, ML ;
PARODI, JC ;
PANETTA, TF ;
BAKAL, CW ;
SUGGS, WD .
AMERICAN JOURNAL OF SURGERY, 1994, 168 (02) :156-162
[10]   Concurrent comparison of endoluminal versus open repair in the treatment of abdominal aortic aneurysms: Analysis of 303 patients by life table method [J].
May, J ;
White, GH ;
Yu, WY ;
Ly, CN ;
Waugh, R ;
Stephen, MS ;
Arulchelvam, M ;
Harris, JP .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (02) :213-220