A preliminary report of a disposable electrical non-fiberoptic endoscope in thoracoscopic surgery

被引:7
作者
Chen, Chih-Hao [1 ,2 ,3 ,4 ]
Chang, Ho [2 ,3 ]
Yang, Liang-Yu [2 ,3 ]
Liu, Hung-Chang [1 ,2 ,3 ,4 ]
Tsung, Tsing-Tshih [2 ,3 ,5 ]
Hung, Tzu-Ti [1 ,4 ]
机构
[1] Mackay Mem Hosp, Dept Thorac Surg, Taipei, Taiwan
[2] Natl Taipei Univ Technol, Grad Inst Mech & Elect Engn, Taipei, Taiwan
[3] Natl Taipei Univ Technol, Inst Mechatron Engn, Taipei, Taiwan
[4] Mackay Med Nursing & Management Coll, Taipei, Taiwan
[5] Chinese Culture Univ, Dept Mech Engn, Taipei, Taiwan
关键词
Thoracoscopy/VATS; Surgery; CMOS CAMERA; ACCURACY; CCD;
D O I
10.1016/j.ijsu.2011.11.005
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Conventional thoracoscopic surgery requires a camera connected to optic fibers and rigid rod lens to ensure the provision of adequate light and quality of real-time images in the operative field. However, the camera, the connected optic fibers and rigid rod lens are not disposable due to cost, which is a concern as regards potential contamination of patients. To decrease such contamination, we designed a disposable device of extremely low cost which we tested in thoracoscopic surgery in animals. Description: A complementary metal-oxide-semiconductor is used for obtaining real-time image at a refresh rate of 30 frames per second. A circumferential light was added by a light emitting diode. We connected wires to a universal serial bus adapter, with which the device can negotiate with a computer so as to control signal retrieval and adjustment of the light as well as focus. The device was designed to be as compact as possible. The contour resembled a conventional thoracoscope, but with no optic fibers and rigid rod lens included. Evaluation: We used the devices to perform routine thoracoscopic surgical procedures, including wedge resection of the lung, lobectomy, esophagectomy, pericardiotomy and pleural biopsy in two 40-kg pigs under general anesthesia. The operating techniques were not altered while using this device. Conclusion: This disposable, electrical non-fiberoptic endoscope has the potential to be easily and safely used in routine thoracoscopic surgery at a minimal cost. Further clinical evaluation will be required to demonstrate the utility in human patients. (C) 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:20 / 24
页数:5
相关论文
共 21 条
[1]  
Bond W W, 1988, Md Med J, V37, P497
[2]   Digital autoradiography using room temperature CCD and CMOS imaging technology [J].
Cabello, Jorge ;
Bailey, Alexis ;
Kitchen, Ian ;
Prydderch, Mark ;
Clark, Andy ;
Turchetta, Renato ;
Wells, Kevin .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (16) :4993-5011
[3]   ELECTRONIC ENDOSCOPY OF THE GASTROINTESTINAL-TRACT - INITIAL EXPERIENCE WITH A NEW TYPE OF ENDOSCOPE THAT HAS NO FIBEROPTIC BUNDLE FOR IMAGING [J].
CLASSEN, M ;
PHILLIP, J .
ENDOSCOPY, 1984, 16 (01) :16-19
[4]   Measuring trunk orientation with a CMOS camera:: Feasibility and accuracy [J].
Gissot, A.-S. ;
Barbieri, G. ;
Iacobelis, M. ;
Paindavoine, M. ;
Perennou, D. .
GAIT & POSTURE, 2007, 26 (04) :603-606
[5]  
Guana R, 2010, Afr J Paediatr Surg, V7, P169, DOI 10.4103/0189-6725.70419
[6]   EFFICACY OF ROUTINE FIBEROPTIC ENDOSCOPE CLEANING AND DISINFECTION FOR KILLING CLOSTRIDIUM-DIFFICILE [J].
HUGHES, CE ;
GEBHARD, RL ;
PETERSON, LR ;
GERDING, DN .
GASTROINTESTINAL ENDOSCOPY, 1986, 32 (01) :7-9
[7]   A CMOS camera-based pulse oximetry imaging system [J].
Humphreys, K. ;
Ward, T. ;
Markham, C. .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :3494-3497
[8]   Microthoracoscopic One-Port Method for Lung Cancer [J].
Iwazaki, Masayuki ;
Inoue, Hiroshi .
ANNALS OF THORACIC SURGERY, 2009, 87 (04) :1250-1252
[9]   CONTAMINATION OF FIBEROPTIC UPPER INTESTINAL ENDOSCOPE [J].
KAPLAN, LR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1979, 242 (05) :415-415
[10]  
Lee K. W., 2005, Hong Kong Medical Journal, V11, P30