HPLC-electrochemical detection with graphite-poly(tetrafluoroethylene) electrode - Determination of the fungicides thiram and disulfiram

被引:52
作者
Fernandez, C [1 ]
Reviejo, AJ [1 ]
Polo, LM [1 ]
Pingarron, JM [1 ]
机构
[1] UNIV COMPLUTENSE MADRID,FAC CHEM,DEPT ANALYT CHEM,E-28040 MADRID,SPAIN
关键词
composite electrodes; disulfiram; graphite-teflon; HPLC; thiram;
D O I
10.1016/0039-9140(96)01899-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The suitability of composite graphite-poly(tetrafluoroethylene) (Teflon) electrodes as amperometric indicator electrodes in HPLC detection is demonstrated. The determination of the fungicides thiram and disulfiram in the presence of ziram has been chosen as an analytical problem. The optimization of working conditions, such as the choice of the organic solvent used in the mobile phase as well as its percentage, the potential applied to the composite electrode, and the time elapsed between mixing the carbamates and the injection, has been accomplished by using the wall-jet flow-cell configuration. The effect of the acetonitrile percentage used in the mobile phase on the retention of thiram, disulfiram, ziram and phenol was evaluated. Resolution up to the baseline can be achieved with 45% acetonitrile. The sensitivity of the determination of thiram and disulfiram in the presence of a constant concentration of ziram is slightly better when using a wall-jet cell; however, the background current is higher, as well as the baseline noise and the time necessary to achieve stabilization of the baseline before the injection. Lower limits of detection for both fungicides, as well as a better repeatability, were obtained when using a thin-layer flow cell configuration. As an application, the determination of thiram in spiked apple samples, at a level of 0.5 mg thiram kg(-1) apple, has been carried out with a mean recovery of 97 +/- 3% for a significance level of 0.05.
引用
收藏
页码:1341 / 1348
页数:8
相关论文
共 16 条
  • [1] AMPEROMETRIC BIOSENSOR BASED ON CARBON-PASTE MIXED WITH ENZYME, LIPID AND CYTOCHROME-C
    AMINE, A
    DENI, J
    KAUFFMANN, JM
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1994, 34 (02): : 123 - 128
  • [2] CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW
    BALDWIN, RP
    THOMSEN, KN
    [J]. TALANTA, 1991, 38 (01) : 1 - 16
  • [3] BAUMANN RA, 1991, RIJKSUNIVERSITEIT GE, V56, P941
  • [4] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF DIMETHYLDITHIOCARBAMATE RESIDUES IN SOME AGRICULTURAL PRODUCTS
    BRANDSTETEROVA, E
    LEHOTAY, J
    LISKA, O
    GARAJ, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 354 : 375 - 381
  • [5] ELECTROANALYSIS WITH ELECTRODES MODIFIED BY INORGANIC FILMS
    COX, JA
    JAWORSKI, RK
    KULESZA, PJ
    [J]. ELECTROANALYSIS, 1991, 3 (09) : 869 - 877
  • [6] GRAPHITE-POLY(TETRAFLUOROETHYLENE) ELECTRODES AS ELECTROCHEMICAL DETECTORS IN FLOWING SYSTEMS
    FERNANDEZ, C
    REVIEJO, AJ
    PINGARRON, JM
    [J]. ANALYTICA CHIMICA ACTA, 1995, 314 (1-2) : 13 - 22
  • [7] DEVELOPMENT OF GRAPHITE-POLY(TETRAFLUOROETHYLENE) COMPOSITE ELECTRODES - VOLTAMMETRIC DETERMINATION OF THE HERBICIDES THIRAM AND DISULFIRAM
    FERNANDEZ, C
    REVIEJO, AJ
    PINGARRON, JM
    [J]. ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 192 - 199
  • [8] HIGH-PRESSURE LIQUID-CHROMATOGRAPHIC DETERMINATION OF FUNGICIDAL DITHIOCARBAMATES
    GUSTAFSSON, KH
    THOMPSON, RA
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1981, 29 (04) : 729 - 732
  • [9] GUSTAFSSON KH, 1983, J AGR FOOD CHEM, V31, P463
  • [10] CONDUCTIVE CARBON CEMENT AS ELECTRODE MATRIX FOR COBALT PHTHALOCYANINE MODIFIED ELECTRODES FOR DETECTION IN FLOWING SOLUTIONS
    HUANG, XJ
    KOK, WT
    [J]. ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 245 - 253