MRI of the breast in patients with metastatic disease of unknown primary

被引:54
作者
Schorn, C [1 ]
Fischer, U [1 ]
Luftner-Nagel, S [1 ]
Westerhof, JP [1 ]
Grabbe, E [1 ]
机构
[1] Univ Gottingen Klinikum, Dept Radiol, D-37075 Gottingen, Germany
关键词
breast neoplasms; breast MR;
D O I
10.1007/s003300050694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to assess the value of contrast-enhanced dynamic breast imaging in patients with carcinoma of unknown primary (CUP). Fourteen patients presenting with metastatic disease compatible with breast cancer (axillary lymph node metastasis: n = 6; supraclavicular lymph node metastasis: n = 1; bone metastasis: n = 3; liver metastasis: n = 3; lung metastasis: n = 1), who had no evidence of tumor in X-ray mammograms and ultrasound, underwent bilateral dynamic breast MR imaging. Suspicious lesions were localized preoperatively using a stereotactic device for MR-guided localization procedures. Magnetic resonance imaging revealed suspicious lesions in 9 of 14 patients. Histopathology revealed invasive carcinoma of the breast in 6 of these patients. Two enhancing lesions were fibroadenomas; one proved to be sclerosing adenosis. In 5 patients MR imaging showed no abnormality. Follow-ups performed up to 1 year after initial treatment revealed no breast cancers in these 5 patients. In patients with metastatic disease of unknown primary, MRI of the breast depicts the primary in a considerable number of cases with normal conventional evaluation.
引用
收藏
页码:470 / 473
页数:4
相关论文
共 14 条
[1]  
Doler W, 1996, RADIOLOGY, V200, P863
[2]   PREOPERATIVE MR MAMMOGRAPHY IN PATIENTS WITH BREAST-CANCER USEFUL INFORMATION OR USELESS EXTRAVAGANCE [J].
FISCHER, U ;
VOSSHENRICH, R ;
PROBST, A ;
BURCHHARDT, H ;
GRABBE, E .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (04) :300-306
[3]   SIGNAL TIME-RELATION OF BENIGN AND MALIGNANT LESIONS IN DYNAMIC 2D-MR IMAGING OF THE BREAST [J].
FISCHER, U ;
VONHEYDEN, D ;
VOSSHENRICH, R ;
VIEWEG, I ;
GRABBE, E .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (04) :287-292
[4]  
Fischer U, 1996, EUR RADIOL, V6, P929
[5]  
Harms S, 1992, Adm Radiol, V11, P111
[6]   MR-IMAGING OF THE BREAST WITH ROTATING DELIVERY OF EXCITATION OFF RESONANCE - CLINICAL-EXPERIENCE WITH PATHOLOGICAL CORRELATION [J].
HARMS, SE ;
FLAMIG, DP ;
HESLEY, KL ;
MEICHES, MD ;
JENSEN, RA ;
EVANS, WP ;
SAVINO, DA ;
WELLS, RV .
RADIOLOGY, 1993, 187 (02) :493-501
[7]  
HEYWANGKOBRUNNE.S, 1996, CONTRAST ENHANCED MR
[8]   PROTOTYPE BREAST COIL FOR MR-GUIDED NEEDLE LOCALIZATION [J].
HEYWANGKOBRUNNER, SH ;
HUYNH, AT ;
VIEHWEG, P ;
HANKE, W ;
REQUARDT, H ;
PAPROSCH, I .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (06) :876-881
[9]   MR-MAMMOGRAPHY OF HIGH-RISK PATIENTS [J].
KAISER, WA ;
MITTELMEIER, O .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (06) :576-581
[10]   Interventional breast MR imaging: Clinical use of a stereotactic localization and biopsy device [J].
Kuhl, CK ;
Elevelt, A ;
Leutner, CC ;
Gieseke, J ;
Pakos, E ;
Schild, HH .
RADIOLOGY, 1997, 204 (03) :667-675