Three-dimensional reconstruction of human bronchial tree in HRCT

被引:6
作者
Fetita, CI [1 ]
Prêteux, F [1 ]
机构
[1] Inst Natl Telecommun, Dept Signal & Image, F-91011 Evry, France
来源
NONLINEAR IMAGE PROCESSING X | 1999年 / 3646卷
关键词
3-D reconstruction; mathematical morphology; connection cost; bronchial tree;
D O I
10.1117/12.341094
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper addresses the issue of 3-D human bronchial tree reconstruction from 2-D segmented slices. The 2-D grey-level slices to be segmented are reconstructed from volumetric data acquired by using a high resolution computerized tomography (HRCT) system operating in spiral mode. The proposed 3-D reconstruction technique consists in three major steps: (1) a fully-automated 2-D segmentation of bronchi performed on each slice and based on mathematical morphology theory; (2) a 3-D oriented and multivalued structure construction characterizing the 3-D topology of the segmented volume and a 3-D oriented propagation based on this structure; and (3) the 3-D reconstruction by using a 3-D mesh technique. Results are presented and discussed.
引用
收藏
页码:281 / 294
页数:14
相关论文
共 10 条
[1]   INVIVO MEASUREMENTS OF AIRWAY REACTIVITY USING HIGH-RESOLUTION COMPUTED-TOMOGRAPHY [J].
BROWN, RH ;
HEROLD, CJ ;
HIRSHMAN, CA ;
ZERHOUNI, EA ;
MITZNER, W .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (01) :208-212
[2]   THE REPRODUCIBILITY OF BRONCHIAL CIRCUMFERENCE MEASUREMENTS USING COMPUTED-TOMOGRAPHY [J].
DESAI, SR ;
WELLS, AU ;
CHEAH, FK ;
COLE, PJ ;
HANSELL, DM .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (795) :257-262
[3]   BRONCHIECTASIS - ASSESSMENT BY THIN-SECTION CT [J].
GRENIER, P ;
MAURICE, F ;
MUSSET, D ;
MENU, Y ;
NAHUM, H .
RADIOLOGY, 1986, 161 (01) :95-99
[4]  
GRENIER P, 1996, MED RADIOLOGY SPIRAL, P185
[5]   ACUTE EFFECTS OF INCREASED INTRAVASCULAR VOLUME AND HYPOXIA ON THE PULMONARY CIRCULATION - ASSESSMENT WITH HIGH-RESOLUTION CT [J].
HEROLD, CJ ;
WETZEL, RC ;
ROBOTHAM, JL ;
HEROLD, SM ;
ZERHOUNI, EA .
RADIOLOGY, 1992, 183 (03) :655-662
[6]   Modeling, segmentation, and caliber estimation of bronchi in high-resolution computerized tomography [J].
Preteux, F ;
Fetita, CI ;
Grenier, P .
STATISTICAL AND STOCHASTIC METHODS IN IMAGE PROCESSING II, 1997, 3167 :58-69
[7]  
PRETEUX F, 1992, MATH MORPHOLOGY IMAG
[8]   MEASUREMENT OF THE INTERNAL SIZE OF BRONCHI USING HIGH-RESOLUTION COMPUTED-TOMOGRAPHY (HRCT) [J].
SENETERRE, E ;
PAGANIN, F ;
BRUEL, JM ;
MICHEL, FB ;
BOUSQUET, J .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (03) :596-600
[9]  
VINCENT L, 1992, SPIE IMAGE ALGEBRA M, V1766, P212
[10]  
WETZEL RC, 1992, REV AM PHYSL SOC