Aneurysm sac pressure monitoring: Effect of technique on interpretation of measurements

被引:7
作者
Hinnen, JW [1 ]
Visser, MJT [1 ]
van Bockel, JH [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Surg, Vasc Surg Sect, Leiden, Netherlands
关键词
AAA; EVAR; aneurysmal sac pressure; pressure sensor;
D O I
10.1016/j.ejvs.2004.11.016
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives. The purpose of this study is to determine the accuracy of measuring pressure with a fluid filled pressure device (needle) and a non-fluid filled pressure device (catheter) inside a thrombosed aneurysmal sac after exclusion from circulation by endovascular grafting. Methods. In a static environment, consisting of a syringe to which a pressure monitoring kit was connected, experiments Were performed to study the influence of the type of device (either needle or catheter) and the effect of the characteristics of the medium on the accuracy and reproducibility of pressure measurements. The pressures obtained with the needle in the different kinds of media were compared with those obtained in blood. Similar experiments were performed using a pressure catheter. Subsequently, pressure measurements were performed in a dynamic and physiological environment. This environment consisted of an artificial circulation in which an aneurysm, constructed of porcine aorta and filled with human aortic thrombus, was mounted. The pressures were compared and analyzed by Bland-Altman plots. Results. Under static conditions, the pressure levels obtained by a needle in blood, starch solution and thrombus were similar. Under identical conditions, pressures obtained by a catheter in starch solution were significant lower than the pressures measured in blood (P < 0.05). Under dynamic pressure conditions the reproducibility of pressures obtained with the needle inserted in the human thrombus was very poor. Conclusion. A needle pressure measuring device, inserted into media like human fibrin thrombus, does not yield accurate and reproducible results. A catheter with a tip-sensor rather than a needle is superior to study the pressure in the aneurysm sac after EVAR.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 13 条
[1]
Treatment of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms: Comparison of transarterial and translumbar techniques - Discussion [J].
Freischlag, JA ;
Baum, RA ;
Brewster, DC ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (01) :29-29
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
Chuter T A, 1997, Cardiovasc Surg, V5, P490, DOI 10.1016/S0967-2109(97)00057-4
[4]
Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks [J].
Dias, NV ;
Ivancev, K ;
Malina, M ;
Resch, T ;
Lindblad, B ;
Sonesson, B .
JOURNAL OF VASCULAR SURGERY, 2004, 39 (06) :1229-1235
[5]
First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms [J].
Ellozy, SH ;
Carroccio, A ;
Lookstein, RA ;
Minor, ME ;
Sheahan, CM ;
Juta, J ;
Cha, A ;
Valenzuela, R ;
Addis, MD ;
Jacobs, MS ;
Teodorescu, VJ ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (03) :405-411
[6]
Rupture of infra-renal aortic aneurysm after endovascular repair: A series from EUROSTAR registry [J].
Fransen, GAJ ;
Vallabhaneni, SR ;
van Marrewijk, CJ ;
Laheij, RJF ;
Harris, PL ;
Buth, J .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 26 (05) :487-493
[7]
Pressure measurements in closed aneurysmal sac during abdominal aortic aneurysm resection [J].
Hans, SS ;
Jareunpoon, O ;
Huang, RR .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (03) :519-525
[8]
Endoleakage after stent-graft treatment of abdominal aneurysm: Implications on pressure and imaging - an in vitro study [J].
Schurink, GWH ;
Aarts, NJM ;
Wilde, J ;
van Baalen, JM ;
Chuter, TAM ;
Kool, LJ ;
van Bockel, JH .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (02) :234-241
[9]
Regarding "Thrombus within an aortic aneurysm does not reduce pressure on the aneurysm wall" - Reply [J].
Schurink, GWH ;
van Bockel, JH .
JOURNAL OF VASCULAR SURGERY, 2001, 33 (03) :661-661
[10]
Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair [J].
Sonesson, B ;
Dias, N ;
Malina, M ;
Olofsson, P ;
Griffin, D ;
Lindblad, B ;
Ivancev, K .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (04) :733-738