Easting plasma glucose is a useful test for the detection of gestational diabetes

被引:66
作者
Reichelt, AJ
Spichler, ER
Branchtein, L
Nucci, LB
Franco, LJ
Schmidt, MI
机构
[1] Univ Fed Rio Grande Sul, Hosp Clin Porto Alegre, BR-90046900 Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande Sul, Sch Med, Dept Social Med, BR-90046900 Porto Alegre, RS, Brazil
[3] Pontificia Univ Catolica Rio Grande do Sul, Sch Med, Dept Internal Med, Porto Alegre, RS, Brazil
[4] Univ Fed Sao Paulo, Dept Prevent Med, Sao Paulo, Brazil
[5] Minist Hlth, Rio De Janeiro, Brazil
关键词
D O I
10.2337/diacare.21.8.1246
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To evaluate fasting plasma glucose as a screening lest for states of gestational diabetes. RESEARCH DESIGN AND METHODS - Baseline data of a cohort conducted in general prenatal care units in Brazil, enrolling 5,579 women aged greater than or equal to 20 years with gestational ages of 24-28 weeks at the time of testing and no previous diagnosis of diabetes. A standardized 2-h 75-g oral glucose tolerance test was performed in 5,010 women. Gestational diabetes and its subcategories-diabetes and impaired glucose tolerance-were defined according to the 1994 World Health Organization panel recommendations. We evaluated screening properties of calculated sensitivity and specificity for fasting plasma glucose with receiver operator characteristic curves. RESULTS - For detection of the subcategory diabetes, a fasting plasma glucose of 89 mg/dl jointly maximizes sensitivity (88%) and specificity (78%), identifying 22% of the women as test-positive. For detection of impaired glucose tolerance, a value of 85 mg/dl jointly maximizes sensitivity and specificity (68%), identifying as test-positive 35% of the women. lowering the cut point to 81 mg/dl increases sensitivity to 81%, but decreases specificity to 54%, labeling as test-positive 49% of the women. CONCLUSIONS - Fasting plasma glucose is a useful test for the screening of both subcategories of gestational diabetes, a threshold of 85 mg/dl being an acceptable option. Effective screening for the subcategory diabetes can be achieved using a cut point of 89 mg/dl. If greater emphasis is placed on the detection of impaired glucose tolerance, a lower value, 81 mg/dl, may be needed.
引用
收藏
页码:1246 / 1249
页数:4
相关论文
共 20 条
[1]  
*AM DIAB ASS, 1997, DIABETES CARE S1, V20, pS44
[2]   CRITERIA FOR SCREENING-TESTS FOR GESTATIONAL DIABETES [J].
CARPENTER, MW ;
COUSTAN, DR .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1982, 144 (07) :768-773
[3]  
Dean AG, 1994, EPI INFO VERSION 6 0
[4]  
Fletcher R.H., 1996, CLIN EPIDEMIOLOGY ES, V3rd
[5]  
Gavin JR, 1997, DIABETES CARE, V20, P1183
[6]   INFLUENCE OF PREGNANCY ON THE 75-G OGTT - A PROSPECTIVE MULTICENTER STUDY [J].
LIND, T ;
PHILLIPS, PR .
DIABETES, 1991, 40 :8-13
[7]   THE 75-G ORAL GLUCOSE-TOLERANCE IN PREGNANCY [J].
MARTIN, FIR ;
RATNAIKE, S ;
WOOTTON, A ;
CONDOS, P ;
SUTER, PEN .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1995, 27 (02) :147-151
[8]   THE DIAGNOSIS OF GESTATIONAL DIABETES [J].
MARTIN, FIR .
MEDICAL JOURNAL OF AUSTRALIA, 1991, 155 (02) :112-112
[9]   Diagnosing diabetes mellitus - Do we need new criteria? [J].
McCance, DR ;
Hanson, RL ;
Pettitt, DJ ;
Bennett, PH ;
Hadden, DR ;
Knowler, WC .
DIABETOLOGIA, 1997, 40 (03) :247-255