A simple, fast and reliable method, based on capillary electrophoresis with electrochemical detection, for the separation and determination of six monosaccharides, namely glucose, galactose, arabinose, fructose, xylose and ribose, in soluble coffees was developed. A copper disk electrode was used as the working electrode. The optimum conditions for separation and detection were 50 mmol L-1 sodium hydroxide buffer (pH 12.7), separation voltage 5 kV and detection potential 0.65 V (vs. Ag/AgCl). The linear ranges were from 5.0 x 10(-3) to 0.5 mmol L-1 for all six sugars. All regression coefficients were >0.99. The detection limits for all the sugars were 1.0 x 10(-3) mmol L-1. The RSD of the peak current was <4.2% (n = 5). The proposed method was applied directly to the separation and determination of the six sugars without prior derivatization, and the assay results were satisfactory.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 18 条
[1]   SENSITIVITY ENHANCEMENT FOR CAPILLARY ELECTROPHORESIS [J].
ALBIN, M ;
GROSSMAN, PD ;
MORING, SE .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :A489-A497
[2]   HPLC analysis of carbohydrates in wines and instant coffees using anion exchange chromatography coupled to pulsed amperometric detection [J].
Bernal, JL ;
DelNozal, MJ ;
Toribio, L ;
DelAlamo, M .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1996, 44 (02) :507-511
[3]   Applications of a copper-modified gold electrode for amperometric detection of polar aliphatic compounds by anion-exchange chromatography [J].
Casella, IG ;
Gatta, M ;
Desimoni, E .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :63-70
[4]   SEPARATION OF SULFONAMIDES AND DETERMINATION OF THE ACTIVE INGREDIENTS IN TABLETS BY MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY [J].
DANG, QX ;
SUN, ZP ;
LING, DK .
JOURNAL OF CHROMATOGRAPHY, 1992, 603 (1-2) :259-266
[5]  
Fang YZ, 1995, CHEM J CHINESE U, V16, P1514
[6]   Determination of adenosine phosphate by co-electroosmotic capillary electrophoresis with amperometric detection [J].
Fu, CG ;
Song, LN ;
Fang, YZ .
ANALYTICA CHIMICA ACTA, 1999, 399 (03) :259-263
[7]  
HIRSCH D, 1999, LEBENSMITTELCHEMIE, V53, P149
[8]  
JIANNONG Y, 1993, ANAL CHEM, V65, P3527
[9]   LIQUID-CHROMATOGRAPHY WITH PULSED ELECTROCHEMICAL DETECTION AT GOLD AND PLATINUM-ELECTRODES [J].
JOHNSON, DC ;
LACOURSE, WR .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :A589-A597
[10]  
LUIS AC, 1993, ANAL CHEM, V65, P476