External Quality Assessment of stat test intralaboratory turnaround times - Pilot study from the members of the Working Group for the Standardization and Promotion of Turnaround Time Control under the auspices of the Comitato Italiano per la Standardizzazione dei Metodi Ematologici e di Laboratorio

被引:3
作者
Negri, M
Carraro, P
Caenaro, G
Cappelletti, P
Giavarina, D
Mezzena, G
Prandini, B
Rampoldi, E
Siviero, F
机构
[1] Osped Civile Maggiore, Chim Clin & Ematol Lab, I-37126 Verona, Italy
[2] Arienda Osped Padova, Med Serv, Lab Urgenza, Padova, Italy
[3] Osped Ca Foncello, Ist Chim Clin & Ematol, Treviso, Italy
[4] Azienda Osped Pordenone, Serv Chim & Microscopia Clin, Pordenone, Italy
[5] Osped Civile Legnago, Lab chim Clin & Microbiol, Legnago, Italy
[6] Osped S Bortolo, Chim Clin & Ematol Lab, Vicenza, Italy
[7] Osped Civile Brescia, Lab Emergenza, Brescia, Italy
[8] Osped Policlin Milano, Lab Urgenza, Milan, Italy
[9] Osped Civile, Lab Chim Clin & Microbiol, Cittadella, Italy
关键词
turnaround time; external quality assessment; stat testing; laboratory medicine;
D O I
10.1515/CCLM.1998.152
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We describe procedures, results and prospects of a pilot program in External Quality Assessment (EQA) of the stat test intralaboratory turnaround times. Our goals are to promote quality by systematic monitoring and comparison of performances by laboratories, continuous investigation into the state of the art of the processes from receipt of sample to transmission of results and creation of a data base for standardization of measures and definition of consensus values for turnaround time. Of 30 laboratories invited to participate, 25 took part, agreeing to record times of arrival and transmission for all determinations of three analytes (blood hemoglobin, serum/plasma potassium and plasma prothrombin time) for seven consecutive days and to continue for one or more further periods of seven days as necessary if there were less than 300 determinations for each analyte. Within a preset time limit, data were sent by e-mail on an Excel(TM) file and we sent back two reports per analyte, showing: i) the graph for time vs. percentage of tests completed and several measures of turnaround time; ii) results of all laboratories in graph form, allowing each laboratory to identify only its own data. The high proportion of participating laboratories among those invited (83 %) encourages us to implement the EQA program systematically, on a half-yearly basis, extending it to all laboratories wishing to participate in Italy or elsewhere in Europe.
引用
收藏
页码:867 / 870
页数:4
相关论文
共 16 条
[1]   IMPROVEMENT IN STAT LABORATORY TURNAROUND TIME - A MODEL CONTINUOUS QUALITY IMPROVEMENT PROJECT [J].
BLUTH, EI ;
LAMBERT, DJ ;
LOHMANN, TP ;
FRANKLIN, DN ;
BOURGEOIS, M ;
KARDINAL, CG ;
DALOVISIO, JR ;
WILLIAMS, MM ;
BECKER, AS .
ARCHIVES OF INTERNAL MEDICINE, 1992, 152 (04) :837-840
[2]  
Burke MD, 1997, AM J CLIN PATHOL, V108, P367
[3]  
Burlina A, 1995, Ann Ist Super Sanita, V31, P163
[4]  
Hallam K, 1988, MLO Med Lab Obs, V20, P39
[5]   USE OF SPECIMEN TURNAROUND TIME AS A COMPONENT OF LABORATORY QUALITY - A COMPARISON OF CLINICIAN EXPECTATIONS WITH LABORATORY PERFORMANCE [J].
HILBORNE, LH ;
OYE, RK ;
MCARDLE, JE ;
REPINSKI, JA ;
RODGERSON, DO .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 92 (05) :613-618
[6]   EVALUATION OF STAT AND ROUTINE TURNAROUND TIMES AS A COMPONENT OF LABORATORY QUALITY [J].
HILBORNE, LH ;
OYE, RK ;
MCARDLE, JE ;
REPINSKI, JA ;
RODGERSON, DO .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (03) :331-335
[7]  
Libeer JC, 1996, EUR J CLIN CHEM CLIN, V34, P665
[8]  
PELLAR TG, 1993, CLIN CHEM, V39, P1054
[9]  
Ricos C, 1996, EUR J CLIN CHEM CLIN, V34, P159
[10]   THE EPIDEMIOLOGY OF DELAYS IN A TEACHING HOSPITAL - THE DEVELOPMENT AND USE OF A TOOL THAT DETECTS UNNECESSARY HOSPITAL DAYS [J].
SELKER, HP ;
BESHANSKY, JR ;
PAUKER, SG ;
KASSIRER, JP .
MEDICAL CARE, 1989, 27 (02) :112-129