Long-term field test of solar PV power generation using one-axis 3-position sun tracker

被引:74
作者
Huang, B. J. [1 ]
Ding, W. L. [1 ]
Huang, Y. C. [1 ]
机构
[1] Natl Taiwan Univ, Dept Mech Engn, New Energy Ctr, Taipei 10764, Taiwan
关键词
Sun tracking PV; One-axis sun tracker; Stand-alone solar PV system; Solar power generation; PERFORMANCE; OPERATION; SYSTEM;
D O I
10.1016/j.solener.2011.05.001
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The 1 axis-3 position (1A-3P) sun tracking PV was built and tested to measure the daily and long-term power generation of the solar PV system. A comparative test using a fixed PV and a 1A-3P tracking PV was carried out with two identical stand-alone solar-powered LED lighting systems. The field test in the particular days shows that the 1A-3P tracking PV can generate 35.8% more electricity than the fixed PV in a partly-cloudy weather with daily-total solar irradiation H-T=11.7 MJ/m(2) day, or 35.6% in clear weather with H-T=18.5 MJ/m(2) day. This indicates that the present 1A-3P tracking PV can perform very close to a dual-axis continuous tracking PV (Kacira et al., 2004). The long-term outdoor test results have shown that the increase of daily power generation of 1A-3P tracking PV increases with increasing daily-total solar irradiation. The increase of monthly-total power generation for 1A-3P sun tracking PV is between 18.5-28.0%. The total power generation increase in the test period from March 1, 2010 to March 31, 2011, is 23.6% in Taipei (an area of low solar energy resource). The long-term performance of the present 1X-3P tracking PV is shown very close to the 1-axis continuous tracking PV in Taiwan (Chang, 2009). If the 1A-3P tracking PV is used in the area of high solar energy resource with yearly-average H-T > 17 MJ/m(2) day, the increase of total long-term power generation with respect to fixed PV will be higher than 37.5%. This is very close to that of dual-axis continuous tracking PV. The 1A-3P tracker can be easily mounted on the wall of a building. The cost of the whole tracker is about the same as the regular mounting cost of a conventional rooftop PV system. This means that there is no extra cost for 1A-3P PV mounted on buildings. The 1A-3P PV is quite suitable for building-integrated applications. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1935 / 1944
页数:10
相关论文
共 18 条
  • [1] Two axes sun tracking system with PLC control
    Abdallah, S
    Nijmeh, S
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (11-12) : 1931 - 1939
  • [2] Use of a reluctance stepper motor for solar tracking based on a programmable logic array (PLA) controller
    Abouzeid, M
    [J]. RENEWABLE ENERGY, 2001, 23 (3-4) : 551 - 560
  • [3] Evaluating multi-axes sun-tracking system at different modes of operation in Jordan
    Abu-Khader, Mazen M.
    Badran, Omar O.
    Abdallah, Salah
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2008, 12 (03) : 864 - 873
  • [4] [Anonymous], P IEEE INT S IND EL
  • [5] Output energy of a photovoltaic module mounted on a single-axis tracking system
    Chang, Tian Pau
    [J]. APPLIED ENERGY, 2009, 86 (10) : 2071 - 2078
  • [6] Feasibility study of one axis three positions tracking solar PV with low concentration ratio reflector
    Huang, B. J.
    Sun, F. S.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (04) : 1273 - 1280
  • [7] Near-maximum-power-point-operation (nMPPO) design of photovoltaic power generation system
    Huang, B. J.
    Sun, F. S.
    Ho, R. W.
    [J]. SOLAR ENERGY, 2006, 80 (08) : 1003 - 1020
  • [8] Development of high-performance solar LED lighting system
    Huang, B. J.
    Wu, M. S.
    Hsu, P. C.
    Chen, J. W.
    Chen, K. Y.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (08) : 1669 - 1675
  • [9] System dynamic model and charging control of lead-acid battery for stand-alone solar PV system
    Huang, B. J.
    Hsu, P. C.
    Wu, M. S.
    Ho, P. Y.
    [J]. SOLAR ENERGY, 2010, 84 (05) : 822 - 830
  • [10] Determining optimum tilt angles and orientations of photovoltaic panels in Sanliurfa, Turkey
    Kacira, M
    Simsek, M
    Babur, Y
    Demirkol, S
    [J]. RENEWABLE ENERGY, 2004, 29 (08) : 1265 - 1275