Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements

被引:633
作者
Parratte, Sebastien [1 ]
Pagnano, Mark W. [1 ]
Trousdale, Robert T. [1 ]
Berry, Daniel J. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
关键词
LOWER-EXTREMITY; ARTHROPLASTY; KINEMATICS;
D O I
10.2106/JBJS.I.01398
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: One long-held tenet of total knee arthroplasty is that implant durability is maximized when postoperative limb alignment is corrected to 0 degrees +/- 3 degrees relative to the mechanical axis. Recently, substantial health-care resources have been devoted to computer navigation systems that allow surgeons to more often achieve that alignment. We hypothesized that a postoperative mechanical axis of 0 degrees +/- 3 degrees would result in better long-term survival of total knee arthroplasty implants as compared with that in a group of outliers. Methods: Clinical and radiographic data were reviewed retrospectively to determine the fifteen-year Kaplan-Meier survival rate following 398 primary total knee arthroplasties performed with cement in 280 patients from 1985 to 1990. Preoperatively, most knees were in varus mechanical alignment (mean and standard deviation, 6 degrees +/- 8.8 degrees of varus [range, 30 degrees of varus to 22 degrees of valgus]), whereas postoperatively most knees were corrected to neutral (mean and standard deviation, 0 degrees +/- 2.8 degrees [range, 8 degrees of varus to 9 degrees of valgus]). Postoperatively, we defined a mechanically aligned group of 292 knees (with a mechanical axis of 0 degrees +/- 3 degrees) and an outlier group of 106 knees (with a mechanical axis of beyond 0 degrees +/- 3 degrees). Results: At the time of the latest follow-up, forty-five (15.4%) of the 292 implants in the mechanically aligned group had been revised for any reason, compared with fourteen (13%) of the 106 implants in the outlier group (p = 0.88); twentyseven (9.2%) of the 292 implants in the mechanically aligned group had been revised because of aseptic loosening, mechanical failure, wear, or patellar problems, compared with eight (7.5%) of the 106 implants in the outlier group (p = 0.88); and seventeen (5.8%) of the 292 implants in the mechanically aligned group had been revised because of aseptic loosening, mechanical failure, or wear, compared with four (3.8%) of the 106 implants in the outlier group (p = 0.49). Conclusions: A postoperative mechanical axis of 0 degrees +/- 3 degrees did not improve the fifteen-year implant survival rate following these 398 modern total knee arthroplasties. We believe that describing alignment as a dichotomous variable (aligned versus malaligned) on the basis of a mechanical axis goal of 0 degrees +/- 3 degrees is of little practical value for predicting the durability of modern total knee arthroplasty implants.
引用
收藏
页码:2143 / 2149
页数:7
相关论文
共 31 条
[1]
BARGREN JH, 1983, CLIN ORTHOP RELAT R, P178
[2]
Navigated total knee replacement - A meta-analysis [J].
Bauwens, Kai ;
Matthes, Gerrit ;
Wich, Michael ;
Gebhard, Florian ;
Hanson, Beate ;
Ekkernkamp, Axel ;
Stengel, Dirk .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (02) :261-269
[3]
Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
Computer Navigation-assisted versus Minimally Invasive TKA Benefits and Drawbacks [J].
Bonutti, Peter M. ;
Dethmers, Daniel ;
Ulrich, Slif D. ;
Seyler, Thorsten M. ;
Mont, Michael A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (11) :2756-2762
[6]
Definition of axial alignment of the lower extremity [J].
Cooke, TDV .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01) :146-147
[7]
A QUANTITATIVE APPROACH TO RADIOGRAPHY OF THE LOWER-LIMB - PRINCIPLES AND APPLICATIONS [J].
COOKE, TDV ;
SCUDAMORE, RA ;
BRYANT, JT ;
SORBIE, C ;
SIU, D ;
FISHER, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :715-720
[8]
D'Lima DD, 2001, CLIN ORTHOP RELAT R, P232
[9]
D'Lima DD, 2001, CLIN ORTHOP RELAT R, P124
[10]
Multicenter determination of in vivo kinematics after total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Haas, BD ;
Stiehl, JB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :37-57