Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index

被引:86
作者
Thompson, RC
Heller, GV
Johnson, LL
Case, JA
Cullom, SJ
Garcia, EV
Jones, PG
Moutray, KL
Bateman, TM
机构
[1] St Lukes Hosp, Mid Amer Heart Inst, Kansas City, MO 64111 USA
[2] Cardiovasc Consultants, Kansas City, MO 64111 USA
[3] Hartford Hosp, Henry Low Heart Ctr, Hartford, CT 06115 USA
[4] Columbia Presbyterian Med Ctr, New York, NY 10032 USA
[5] Emory Univ, Atlanta, GA 30322 USA
关键词
attenuation correction; single photon emission computed tomography; body mass index;
D O I
10.1016/j.nuclcard.2004.12.298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Obesity is a growing problem in the United States, and attenuation artifacts are more prevalent in this patient group. This study evaluated the impact of attenuation correction in patients with a high body mass index (BMI). Methods and Results. Three readers interpreted gated attenuation-corrected and non-attenuation-corrected rest/stress technetium 99m sestamibi myocardial perfusion imaging results in 116 patients (BMI < 30, n = 60; BMI >= 30, n = 56) who had coronary angiography no more than 60 days after imaging. Readers were blinded to all clinical information and as to whether myocardial perfusion imaging was attenuation-corrected or non-attenuation-corrected. Sensitivity, specificity, and accuracy for detection of coronary artery disease of 70% or greater for attenuation-corrected versus non-attenuation-corrected single photon emission computed tomography (SPECT) were 86% versus 89%, 79% versus 50%, and 84% versus 79%, respectively. Sensitivity, specificity, and accuracy for attenuation-corrected versus non-attenuation-corrected SPECT for patients with BMI less than 30 were 90% versus 90%, 82% versus 64%, and 88% versus 85%, respectively. For BMI of 30 or greater, the results were 82% versus 87%, 76% versus 41%, and 80% versus 73%, respectively. There was a significant difference in specificity overall (P = .02) and for the category of BMI of 30 or greater (P = .03). Conclusions. This study demonstrates that electrocardiography-gated attenuation-corrected Tc-99m sestamibi SPECT myocardial perfusion imaging improves specificity compared with electrocardiography-gated non-attenuation-corrected SPECT myocardial perfusion imaging, especially in patients with BMI of 30 or greater.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 36 条
[1]  
Agresti A., 1990, Analysis of categorical data
[2]   Annual deaths attributable to obesity in the United States [J].
Allison, DB ;
Fontaine, KR ;
Manson, JE ;
Stevens, J ;
VanItallie, TB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (16) :1530-1538
[3]   American Society of Nuclear Cardiology position statement on electrocardiographic gating of myocardial perfusion SPECT scintigrams [J].
Bateman, TM ;
Berman, DS ;
Heller, GV ;
Brown, KA ;
Cerqueira, MD ;
Verani, MS ;
Udelson, JE .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (04) :470-471
[4]  
Billington CJ, 2000, ARCH INTERN MED, V160, P898, DOI 10.1001/archinte.160.7.898
[5]  
BROWN DB, GLOBAL EPIDEMIC OBES
[6]  
CASE JA, 2000, J NUCL CARDIOL, V7, pS11
[7]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[8]  
Cullom SJ, 2000, J NUCL MED, V41, P860
[9]  
CULLOM SJ, 2000, J NUCL MED, V41
[10]  
DEPUEY E, 1995, J NUCL MED, V36, P952