Comparison of Different Spectral Domain Optical Coherence Tomography Scanning Areas for Glaucoma Diagnosis

被引:153
作者
Rao, Harsha L. [1 ,2 ]
Zangwill, Linda M. [1 ]
Weinreb, Robert N. [1 ]
Sample, Pamela A. [1 ]
Alencar, Luciana M. [1 ,3 ]
Medeiros, Felipe A. [1 ]
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
[2] L V Prasad Eye Inst, Hyderabad, Andhra Pradesh, India
[3] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
关键词
NERVE-FIBER LAYER; MACULAR THICKNESS MEASUREMENTS; STRATUS OCT; CLINICAL-TRIALS; FOURIER-DOMAIN; TESTS; EYES; RESOLUTION; ACCURACY; ABILITY;
D O I
10.1016/j.ophtha.2010.01.031
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.
引用
收藏
页码:1692 / U55
页数:9
相关论文
共 34 条
[1]
Distribution-free ROC analysis using binary regression techniques [J].
Alonzo, TA ;
Pepe, MS .
BIOSTATISTICS, 2002, 3 (03) :421-432
[2]
Comparison of diagnostic accuracy of heidelberg retina tomograph II and heidelberg retina tomograph 3 to discriminate glaucomatous and nonglaucomatous eyes [J].
De Leon-Ortega, Julio E. ;
Sakata, Lisandro M. ;
Monheit, Blythe E. ;
Mcgwin, Gerald, Jr. ;
Arthur, Stella N. ;
Girkin, Christopher A. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (04) :525-532
[3]
Subjective and objective optic nerve assessment in African Americans and whites [J].
Girkin, CA ;
McGwin, G ;
Long, C ;
DeLeon-Ortega, J ;
Graf, CM ;
Everett, AW .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (07) :2272-2278
[4]
ACCOUNTING FOR THE CORRELATION BETWEEN FELLOW EYES IN REGRESSION-ANALYSIS [J].
GLYNN, RJ ;
ROSNER, B .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (03) :381-387
[5]
Glaucoma detection by Stratus OCT [J].
Hougaard, Jesper Leth ;
Heijl, Anders ;
Bengtsson, Boel .
JOURNAL OF GLAUCOMA, 2007, 16 (03) :302-306
[6]
USERS GUIDES TO THE MEDICAL LITERATURE .3. HOW TO USE AN ARTICLE ABOUT A DIAGNOSTIC-TEST .A. ARE THE RESULTS OF THE STUDY VALID [J].
JAESCHKE, R ;
GUYATT, G ;
SACKETT, DL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (05) :389-391
[7]
Ability of Stratus OCT to Detect Progressive Retinal Nerve Fiber Layer Atrophy in Glaucoma [J].
Lee, Eun Ji ;
Kim, Tae-Woo ;
Park, Ki Ho ;
Seong, Mincheol ;
Kim, Hyunjoong ;
Kim, Dong Myung .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (02) :662-668
[8]
Empirical evidence of design-related bias in studies of diagnostic tests [J].
Lijmer, JG ;
Mol, BW ;
Heisterkamp, S ;
Bonsel, GJ ;
Prins, MH ;
van der Meulen, JHP ;
Bossuyt, PMM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (11) :1061-1066
[9]
Comparison of retinal nerve fiber layer thickness and optic disk algorithms with optical coherence tomography to detect glaucoma [J].
Manassakorn, A ;
Nouri-Mahdavi, K ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) :105-115
[10]
Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Vessani, RM ;
Susanna, R ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) :44-55