Detection of E-coli using a microfluidics-based antibody biochip detection system

被引:53
作者
Stokes, DL [1 ]
Griffin, GD [1 ]
Vo-Dinh, T [1 ]
机构
[1] Oak Ridge Natl Lab, Div Life Sci, Adv Monitoring Dev Grp, Oak Ridge, TN 37831 USA
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 369卷 / 3-4期
关键词
D O I
10.1007/s002160000660
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work demonstrates the detection of E. coli using a 2-dimensional photosensor array biochip which is efficiently equipped with a microfluidics sample/reagent delivery system for on-chip monitoring of bioassays. The biochip features a 4 x 4 array of independently operating photodiodes that are integrated along with amplifiers, discriminators and logic circuitry on a single platform. The microfluidics system includes a single 0.4 mt reaction chamber which houses a sampling platform that selectively captures detection probes from a sample through the use of immobilized bioreceptors. The independently operating photodiodes allow simultaneous monitoring of multiple samples. In this study the sampling platform is a cellulosic membrane that is exposed to E. coli organisms and subsequently analyzed using a sandwich immunoassay involving a Cy5-labeled antibody probe. The combined effectiveness of the integrated circuit (IC) biochip and the immunoassay is evaluated for assays performed both by conventional laboratory means followed by detection with the IC biochip, and through the use of the mi crofluidics system for on-chip detection. Highlights of the studies show that the biochip has a linear dynamic range of three orders of magnitude observed for conventional assays, and can detect 20 E. cull organisms. Selective detection of E. Loll in a complex medium, milk diluent, is also reported for both off-chip and on-chip assays.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 33 条
[1]  
Anderson RC, 1998, TOP CURR CHEM, V194, P117
[2]   Modifications to methods for the enumeration and detection of injured Escherichia coli O157:H7 in foods [J].
Blackburn, CD ;
McCarthy, JD .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2000, 55 (1-3) :285-290
[3]   Comparison of the recoveries of Escherichia coli and total coliforms from drinking water by the MI agar method and the US environmental protection agency-approved membrane filter method [J].
Brenner, KP ;
Rankin, CC ;
Sivaganesan, M ;
Scarpino, PV .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1996, 62 (01) :203-208
[4]   NEW MEDIUM FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND ESCHERICHIA-COLI IN WATER [J].
BRENNER, KP ;
RANKIN, CC ;
ROYBAL, YR ;
STELMA, GN ;
SCARPINO, PV ;
DUFOUR, AP .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (11) :3534-3544
[5]   Interlaboratory evaluation of MI agar and the US Environmental Protection Agency-approved membrane filter method for the recovery of total coliforms and Escherichia coli from drinking water [J].
Brenner, KP ;
Rankin, CC ;
Sivaganesan, M .
JOURNAL OF MICROBIOLOGICAL METHODS, 1996, 27 (2-3) :111-119
[6]  
Bulte M, 1998, FLEISCHWIRTSCHAFT, V78, P690
[7]  
Eckner KF, 1998, APPL ENVIRON MICROB, V64, P3079
[8]   Specificity of a conductance assay for enumeration of Escherichia coli from broiler carcass rinse samples containing genetically similar species [J].
Edmiston, AL ;
Russell, SM .
JOURNAL OF FOOD PROTECTION, 2000, 63 (02) :264-267
[9]  
EGGERS M, 1994, BIOTECHNIQUES, V17, P516
[10]   EZ coli rapid detection system: A rapid method for the detection of Escherichia coli O157 in meat and other foods [J].
FirstenbergEden, R ;
Sullivan, NM .
JOURNAL OF FOOD PROTECTION, 1997, 60 (03) :219-225