High-Throughput Selection, Enumeration, Electrokinetic Manipulation, and Molecular Profiling of Low-Abundance Circulating Tumor Cells Using a Microfluidic System

被引:159
作者
Dharmasiri, Udara [1 ,2 ]
Njoroge, Samuel K. [1 ,2 ]
Witek, Malgorzata A. [1 ,2 ]
Adebiyi, Morayo G. [2 ]
Kamande, Joyce W. [1 ,2 ]
Hupert, Mateusz L. [1 ,2 ]
Barany, Francis [4 ]
Soper, Steven A. [1 ,2 ,3 ,5 ]
机构
[1] Louisiana State Univ, Ctr Biomodular Multiscale Syst, Baton Rouge, LA 70820 USA
[2] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
[3] Louisiana State Univ, Dept Mech Engn, Baton Rouge, LA 70803 USA
[4] Weill Cornell Med Coll, Dept Mol Biol, New York, NY 10065 USA
[5] Ulsan Natl Inst Sci & Technol, Sch Nanobiosci & Chem Engn, Ulsan, South Korea
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
COLORECTAL-CANCER; PERIPHERAL-BLOOD; ARRAY; BIOMARKERS; TRANSPORT; MOTION;
D O I
10.1021/ac103172y
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A circulating tumor cell (CTC) selection microfluidic device was integrated to an electrokinetic enrichment device for preconcentrating CTCs directly from whole blood to allow for the detection of mutations contained within the genomic DNA of the CTCs. Molecular profiling of CTCs can provide important clinical information that cannot be garnered simply by enumerating the selected CTCs. We evaluated our approach using SW620 and HT29 cells (colorectal cancer cell lines) seeded into whole blood as a model system. Because SW620 and HT29 cells overexpress the integral membrane protein EpCAM, they could be immunospecifically selected using a microfluidic device containing anti-EpCAM antibodies immobilized to the walls of a selection bed. The microfluidic device was operated at an optimized flow rate of 2 mm s(-1), which allowed for the ability to process 1 mL of whole blood in < 40 min. The selected CTCs were then enzymatically released from the antibody selection surface and hydrodynamically transported through a pair of Pt electrodes for conductivity-based enumeration. The efficiency of CTC selection was found to be 96% +/- 4%. Following enumeration, the CTCs were hydrodynamically transported at a flow rate of 1 mu L min(-1) to an on-chip electromanipulation unit, where they were electrophoretically withdrawn from the bulk hydrodynamic flow and directed into a receiving reservoir. Using an electric field of 100 V cm(-1), the negatively charged CTCs were enriched into an anodic receiving reservoir to a final volume of 2 mu L, providing an enrichment factor of 500. The collected CTCs could then be searched for point mutations using a PCR/LDR/capillary electrophoresis assay. The DNA extracted from the CTCs was subjected to a primary polymerase chain reaction (PCR) with the amplicons used for a ligase detection reaction (LDR) to probe for KRAS oncogenic point mutations. Point mutations in codon 12 of the KRAS gene were successfully detected in the SW620 CTCs for samples containing < 10 CTCs in 1 mL of whole blood. However, the HT29 cells did not contain these mutations, consistent with their known genotype.
引用
收藏
页码:2301 / 2309
页数:9
相关论文
共 39 条
[1]
Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor [J].
Adams, Andre A. ;
Okagbare, Paul I. ;
Feng, Juan ;
Hupert, Matuesz L. ;
Patterson, Don ;
Goettert, Jost ;
McCarley, Robin L. ;
Nikitopoulos, Dimitris ;
Murphy, Michael C. ;
Soper, Steven A. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (27) :8633-8641
[2]
Circulating Tumor Cell Analysis: Technical and Statistical Considerations for Application to the Clinic [J].
Allan, Alison L. ;
Keeney, Andmichael .
JOURNAL OF ONCOLOGY, 2010, 2010
[3]
Tumor cells circulate in the peripheral blood of all major carcinomas but not in healthy subjects or patients with nonmalignant diseases [J].
Allard, WJ ;
Matera, J ;
Miller, MC ;
Repollet, M ;
Connelly, MC ;
Rao, C ;
Tibbe, AGJ ;
Uhr, JW ;
Terstappen, LWMM .
CLINICAL CANCER RESEARCH, 2004, 10 (20) :6897-6904
[4]
Targeted In-Gel MRM: A Hypothesis Driven Approach for Colorectal Cancer Biomarker Discovery in Human Feces [J].
Ang, Ching-Seng ;
Nice, Edouard C. .
JOURNAL OF PROTEOME RESEARCH, 2010, 9 (09) :4346-4355
[5]
The use of molecular profiling of early colorectal cancer to predict micrometastases [J].
Bilchik, AJ ;
Nora, DT ;
Saha, S ;
Turner, R ;
Wiese, D ;
Kuo, C ;
Ye, X ;
Morton, DL ;
Hoon, DSB .
ARCHIVES OF SURGERY, 2002, 137 (12) :1377-1383
[6]
BOUCHE O, 2010, CANC TREAT REV, V36, P10
[7]
Phenotypic and genetic characterization of circulating tumor cells by combining immunomagnetic selection and FICTION techniques [J].
Campos, Maria ;
Prior, Celia ;
Warleta, Fernando ;
Zudaire, Isabel ;
Ruiz-Mora, Jesus ;
Catena, Raul ;
Calvo, Alfonso ;
Gaforio, Jose J. .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2008, 56 (07) :667-675
[8]
The forward rate of binding of surface-tethered reactants: Effect of relative motion between two surfaces [J].
Chang, KC ;
Hammer, DA .
BIOPHYSICAL JOURNAL, 1999, 76 (03) :1280-1292
[9]
Isolation and characterization of circulating tumor cells in patients with metastatic colorectal cancer [J].
Cohen, Steven J. ;
Alpaugh, R. Katherine ;
Gross, Steve ;
O'Hara, Shawn M. ;
Smirnov, Denis A. ;
Ferstappen, Leon W. M. M. ;
Allard, W. Jeffrey ;
Bilbee, Maryann ;
Cheng, Jonathan D. ;
Hoffman, John P. ;
Lewis, Nancy L. ;
Pellegrino, Ann ;
Rogatko, Andre ;
Sigurdson, Elin ;
Wang, Hao ;
Watson, James C. ;
Weiner, Louis M. ;
Meropol, Neal J. .
CLINICAL COLORECTAL CANCER, 2006, 6 (02) :125-132
[10]
Circulating tumor cells, disease progression, and survival in metastatic breast cancer [J].
Cristofanilli, M ;
Budd, GT ;
Ellis, MJ ;
Stopeck, A ;
Matera, J ;
Miller, MC ;
Reuben, JM ;
Doyle, GV ;
Allard, WJ ;
Terstappen, LWMM ;
Hayes, DF .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (08) :781-791