Effect of ventilation systems and air filters on decay rates of particles produced by indoor sources in an occupied townhouse

被引:120
作者
Howard-Reed, C
Wallace, LA
Emmerich, SJ
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] US EPA, Reston, VA 20191 USA
关键词
fine particles; coarse particles; deposition; filtration; residential indoor air quality;
D O I
10.1016/j.atmosenv.2003.09.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Several studies have shown the importance of particle losses in real homes due to deposition and filtration; however, none have quantitatively shown the impact of using a central forced air fan and in-duct filter on particle loss rates. In an attempt to provide such data, we measured the deposition of particles ranging from 0.3 to 10 mum in an occupied townhouse and also in an unoccupied test house. Experiments were run with three different sources (cooking with a gas stove, citronella candle, pouring kitty litter), with the central heating and air conditioning (HAC) fan on or off, and with two different types of in-duct filters (electrostatic precipitator and ordinary furnace filter). Particle size, HAC fan operation, and the electrostatic precipitator had significant effects on particle loss rates. The standard furnace filter had no effect. Surprisingly, the type of source (combustion vs. mechanical generation) and the type of furnishings (fully furnished including carpet vs. largely unfurnished including mostly bare floor) also had no measurable effect on the deposition rates of particles of comparable size. With the HAC fan off, average deposition rates varied from 0.3 h(-1) for the smallest particle range (0.3-0.5 mum) to 5.2 h(-1) for particles greater than 10 mum. Operation of the central HAC fan approximately doubled these rates for particles < 5 mum, and increased rates by 2 h(-1) for the larger particles. An in-duct electrostatic precipitator increased the loss rates compared to the fan-off condition by factors of 5-10 for particles < 2.5 mum, and by a factor of 3 for 2.5-5.0 mum particles. In practical terms, use of the central fan alone could reduce indoor particle concentrations by 25-50%, and use of an in-duct ESP could reduce particle concentrations by 55-85% compared to fan-off conditions. Published by Elsevier Ltd.
引用
收藏
页码:5295 / 5306
页数:12
相关论文
共 21 条
[1]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[2]  
[Anonymous], E74100 ASTM
[3]   Measurement and simulation of the IAQ impact of particle air cleaners in a single-zone building [J].
Emmerich, SJ ;
Nabinger, SJ .
HVAC&R RESEARCH, 2001, 7 (03) :223-244
[4]   Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios [J].
Fogh, CL ;
Byrne, MA ;
Roed, J ;
Goddard, AJH .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (15) :2193-2203
[5]  
FUGLER D, 2002, INDOOR AIR 2002, V1, P868
[6]  
Lai ACK, 2000, J AEROSOL SCI, V31, P463
[7]   Particle deposition indoors: a review [J].
Lai, ACK .
INDOOR AIR, 2002, 12 (04) :211-214
[8]   Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior [J].
Long, CM ;
Suh, HH ;
Catalano, PJ ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (10) :2089-2099
[9]   Penetration of ambient fine particles into the indoor environment [J].
Mosley, RB ;
Greenwell, DJ ;
Sparks, LE ;
Guo, Z ;
Tucker, WG ;
Fortmann, R ;
Whitfield, C .
AEROSOL SCIENCE AND TECHNOLOGY, 2001, 34 (01) :127-136
[10]   MATHEMATICAL-MODELING OF INDOOR AEROSOL DYNAMICS [J].
NAZAROFF, WW ;
CASS, GR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (02) :157-166