The overall objective of this study was to develop an optical fluorosensor (optode) for real-time measurements of ammonium concentrations in natural liquid samples. An NH4+ optode that can be used at such conditions should be analyte specific and independent of ionic strength and pH within a range normally found in such samples (pH 6-8; I-tot 0-700 mM). Additional desired sensor feature is a short response time (preferably minutes or less). This work presents an NH4+ fluorosensor that utilizes similar principles previously described for a K+ selective fluorosensor, i.e. coextraction of a nonactin-ammonium complex and a solvatochromic dye in a hydrogel-ether emulsion. The sensor was tested for its selectivity for ammonium ions compared to other solutes from which interferences frequently have been reported, e.g. K+ and H+. Furthermore, sensor performance at different ionic strengths (I) was evaluated. The ammonium fluorosensor was found to be (i) analyte specific with a selectivity coefficient (K-NH4+.K+(opt)) of 7 x 10(-2), i.e. sensor membranes are about twice as selective to ammonium relative potassium compared to previous studies of electrochemical sensors; (ii) pH independent within the interval 6.0-7.8; (iii) dependent on ionic strength within the interval 100-700 mM, with optimal performance at lowest I-tot evaluated (100 mm); (iv) has a response time of less than 4 min; (v) has the ability to reversibly sense NH4+ even at muM levels. Sensor dynamic range was estimated as 10 muM-100 mM NH4+ in a sample matrix with ionic strength of 100 mM. Construction, configuration and composition of sensor membranes make the ammonium fluorosensor several times reusable, with a sensor shelf life time of at least 8 months. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 225
页数:11
相关论文
共 29 条
[1]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[2]   AMMONIUM-SELECTIVE NEUTRAL CARRIER MEMBRANE ELECTRODES [J].
DEGAWA, H ;
SHINOZUKA, N ;
HAYANO, S .
NIPPON KAGAKU KAISHI, 1980, (10) :1462-1468
[3]   MEMBRANE MODEL FOR NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES CONTAINING IONIC SITES [J].
EUGSTER, R ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1993, 65 (06) :689-695
[4]  
GRYNKIEWICZ G, 1985, J BIOL CHEM, V260, P3440
[5]   Overcoming the pH dependency of optical sensors: a pH-independent chloride sensor based on co-extraction [J].
Huber, C ;
Werner, T ;
Krause, C ;
Wolfbeis, OS ;
Leiner, MJP .
ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) :137-143
[6]  
JANATA J, 1992, ANAL CHEM, P921
[7]  
KORENAGA T, 1980, ANAL CHIM ACTA, V120, P391
[8]   pH-insensitive ion selective optode: A coextraction-based sensor for potassium ions [J].
Krause, C ;
Werner, T ;
Huber, C ;
Wolfbels, OS ;
Leiner, MJP .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1544-1548
[9]   Multilayer potassium sensor based on solid-state coextraction [J].
Krause, C ;
Werner, T ;
Wolfbeis, OS .
ANALYTICAL SCIENCES, 1998, 14 (01) :163-167
[10]  
Lakowicz J.R., 2004, PRINCIPLES FLUORESCE, VSecond