Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurements - A prospective, randomly assigned, blinded study

被引:133
作者
Thomson, HL
Basmadjian, AJ
Rainbird, AJ
Razavi, M
Avierinos, JF
Pellikka, PA
Bailey, KR
Breen, JF
Enriquez-Sarano, M
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiovasc Dis & Internal Med, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Biostat Sect, Rochester, MN 55905 USA
关键词
D O I
10.1016/S0735-1097(01)01416-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to assess the impact of contrast injection and harmonic imaging, on the measure by echocardiography of left ventricular (LV) remodeling. BACKGROUND Left ventricular remodeling is a precursor of LV dysfunction, but the impact of contrast injection and harmonic imaging on the accuracy or reproducibility of echocardiography is unclear. METHODS We prospectively collected LV images by using simultaneous methods. Then, LV volumes were measured off line, in blinded manner and in random order. The accuracy of echocardiography was determined in comparison to electron beam computed tomography (EBCT) in 26 patients. The reproducibility of echocardiography was assessed by three blinded observers with different training levels in 32 patients. RESULTS End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF), as measured by EBCT (195 +/- 55, 58 +/- 24 and 137 +/- 35 ml and 71 +/- 5%, respectively) and echocardiography with harmonic imaging and contrast injection (194 +/- 51, 55 +/- 20 and 140 +/- 35 ml and 72 +/- 4%, respectively), showed no differences (all p > 0.15) and excellent correlations (all r > 0.87). In contrast, echocardiography using harmonic imaging without contrast injection underestimated the EBCT results (all p < 0.01). Reproducibility was superior with rather than without contrast injection for intraobserver and interobserver variabilities (all p < 0.001). Values measured by different observers were different without contrast injection, but were similar with contrast injection (all p > 0.18). Consequently, intrinsic patient differences represented a larger and almost exclusive proportion of global variability with contrast injection for EDV (94 vs. 79%), ESV (93 vs. 82%), SV (87 vs. 53%) and EF (84 vs. 41%), as compared with harmonic imaging without contrast injection (all p < 0.005). CONCLUSIONS For assessment of LV remodeling, echocardiography with harmonic imaging and contrast injection improved the accuracy and reproducibility, as compared with imaging without contrast injection. With contrast injection, variability was almost exclusively due to intrinsic patient differences. Therefore, when evaluation of LV remodeling is deemed important, assessment after contrast injection should be the preferred echocardiographic approach. (C) 2001 by the American College of Cardiology.
引用
收藏
页码:867 / 875
页数:9
相关论文
共 38 条
  • [2] SUPERIORITY OF VISUAL VERSUS COMPUTERIZED ECHOCARDIOGRAPHIC ESTIMATION OF RADIONUCLIDE LEFT-VENTRICULAR EJECTION FRACTION
    AMICO, AF
    LICHTENBERG, GS
    REISNER, SA
    STONE, CK
    SCHWARTZ, RG
    MELTZER, RS
    [J]. AMERICAN HEART JOURNAL, 1989, 118 (06) : 1259 - 1265
  • [3] Image enhancement by noncontrast harmonic echocardiography. Part II. Quantitative assessment with use of contrast-to-speckle ratio
    Belohlavek, M
    Tanabe, K
    Mulvagh, SL
    Foley, DA
    Greenleaf, JF
    Seward, JB
    [J]. MAYO CLINIC PROCEEDINGS, 1998, 73 (11) : 1066 - 1070
  • [4] Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent - Results of a phase III multicenter trial
    Cohen, JL
    Cheirif, J
    Segar, DS
    Gillam, LD
    Gottdiener, JS
    Hausnerova, E
    Bruns, DE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) : 746 - 752
  • [5] Cardiac remodeling-concepts and clinical implications: A consensus paper from an international forum on cardiac remodeling
    Cohn, JN
    Ferrari, R
    Sharpe, N
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (03) : 569 - 582
  • [7] DETERMINANTS OF SURVIVAL AND LEFT-VENTRICULAR PERFORMANCE AFTER MITRAL-VALVE REPLACEMENT
    CRAWFORD, MH
    SOUCHEK, J
    OPRIAN, CA
    MILLER, DC
    RAHIMTOOLA, S
    GIACOMINI, JC
    SETHI, G
    HAMMERMEISTER, KE
    [J]. CIRCULATION, 1990, 81 (04) : 1173 - 1181
  • [8] OPACIFICATION AND BORDER DELINEATION IMPROVEMENT IN PATIENTS WITH SUBOPTIMAL ENDOCARDIAL BORDER DEFINITION IN ROUTINE ECHOCARDIOGRAPHY - RESULTS OF THE PHASE-III ALBUNEX MULTICENTER TRIAL
    CROUSE, LJ
    CHEIRIF, J
    HANLY, DE
    KISSLO, JA
    LABOVITZ, AJ
    RAICHLEN, JS
    SCHUTZ, RW
    SHAH, PM
    SMITH, MD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) : 1494 - 1500
  • [9] Echocardiographic assessment of left ventricular remodeling: Are left ventricular diameters suitable tools?
    Dujardin, KS
    EnriquezSarano, M
    Rossi, A
    Bailey, KR
    Seward, JB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) : 1534 - 1541
  • [10] EFFECTIVE MITRAL REGURGITANT ORIFICE AREA - CLINICAL USE AND PITFALLS OF THE PROXIMAL ISOVELOCITY SURFACE-AREA METHOD
    ENRIQUEZSARANO, M
    MILLER, FA
    HAYES, SN
    BAILEY, KR
    TAJIK, AJ
    SEWARD, JB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (03) : 703 - 709